Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque

被引:265
作者
Achenbach, Stephan [1 ]
Boehmer, Kerstin [1 ]
Pflederer, Tobias [1 ]
Ropers, Dieter [1 ]
Seltmann, Martin [1 ]
Lell, Michael [2 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Uder, Michael [2 ]
Daniel, Werner G. [1 ]
Marwan, Mohamed [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
关键词
Attentuation; Computed tomography; Kernel; Plaque;
D O I
10.1016/j.jcct.2010.01.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The computed tomographic (CT) attenuation of coronary atherosclerotic plaque has been proposed as a marker for tissue characterization and may thus potentially contribute to the assessment of plaque instability. OBJECTIVE: We analyzed the influence of reconstruction parameters on CT attenuation measured within noncalcified coronary atherosclerotic lesions. METHODS: Seventy-two patients were studied by contrast-enhanced dual-source CT coronary angiography (330 millisecond rotation time, 2 X 64 X 0.6 mm collimation, 120 kV, 400 mAs, 80 mL contrast agent intravenously at 6 mL/s), and a total of 100 distinct noncalcified coronary atherosclerotic plaques were identified. Image data sets were reconstructed with a soft (B20f), medium soft (B26f), and sharp (B46f) reconstruction kernel. With the medium soft kernel, image data sets were reconstructed with a slice thickness/increment of 0.6/0.3 mm, 0.75/0.4 mm, and 1.0/0.5mm. Within each plaque, CT attenuation was measured. RESULTS: Mean CT attenuation using the medium soft kernel was 109 +/- 58 HU (range, -16 to 168 HU). Using the soft kernel, mean density was 113 +/- 57 HU (range, -13 to 169 HU), and using a sharp kernel, mean density was 97 +/- 49 HU (range, -23 to 131 KU). Similarly, reconstructed slice thickness had a significant influence on the measured CT attenuation (mean values for medium soft kernel: 102 +/- 52 HU versus 109 +/- 58 HU versus 113 +/- 57 HU for 0.6mm, 0.75-mm, and 1.0-mm slice thickness). The differences between 0.75-mm and 0.6-mm slice thickness (P = 0.05) and between medium sharp and sharp kernels (P = 0.02) were statistically significant. CONCLUSIONS: Image reconstruction significantly influences CT attenuation of noncalcified coronary atherosclerotic plaque. With decreasing spatial resolution (softer kernel or thicker slices), CT attenuation increases significantly. Using absolute CT attenuation values for plaque characterization may therefore be problematic. (C) 2010 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 37 条
[1]   Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography [J].
Achenbach, S ;
Ropers, D ;
Hofmann, U ;
MacNeill, B ;
Baum, U ;
Pohle, K ;
Brady, TJ ;
Pomerantsev, E ;
Ludwig, J ;
Flachskampf, FA ;
Wicky, S ;
Jang, IK ;
Daniel, WG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :842-847
[2]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[3]  
Achenbach Stephan, 2007, J Cardiovasc Comput Tomogr, V1, P3, DOI 10.1016/j.jcct.2007.04.007
[4]   Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease [J].
Achenbach, Stephan ;
Ropers, Ulrike ;
Kuettner, Axel ;
Anders, Katharina ;
Pflederer, Tobias ;
Komatsu, Sei ;
Bautz, Werner ;
Daniel, Werner G. ;
Ropers, Dieter .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (02) :177-186
[5]   Reproducible coronary plaque quantification by multislice computed tomography [J].
Bruining, Nico ;
Roelandt, Jos R. T. C. ;
Palumbo, Alessandro ;
La Grutta, Ludovico ;
Cademartiri, Filippo ;
de Feijter, Pirn J. ;
Mollet, Nico ;
van Domburg, Ron T. ;
Serruys, P. W. ;
Hamers, Ronald .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (06) :857-865
[6]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[7]   Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography [J].
Cademartiri, Filippo ;
La Grutta, Ludovico ;
Runza, Giuseppe ;
Palumbo, Alessandro ;
Maffei, Erica ;
Mollet, Nico R. A. ;
Bartolotta, Tommaso Vincenzo ;
Somers, Pamela ;
Knaapen, Michiel ;
Verheye, Stefan ;
Midiri, Massimo ;
Hamers, Ronald ;
Bruining, Nico .
EUROPEAN RADIOLOGY, 2007, 17 (07) :1842-1849
[8]   Characterization of coronary atherosclerotic plaques by multidetector computed tomography [J].
Carrascosa, PM ;
Capuñay, CM ;
Garcia-Merletti, P ;
Carrascosa, J ;
Garcia, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (05) :598-602
[9]   Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular sound [J].
Caussin, C ;
Ohanessian, A ;
Ghostine, S ;
Jacq, L ;
Lancelin, B ;
Dambrin, G ;
Sigal-Cinqualbre, A ;
Angel, CY ;
Paul, JF .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (01) :99-104
[10]  
Cheng Victor Y, 2009, J Cardiovasc Comput Tomogr, V3, P312, DOI 10.1016/j.jcct.2009.07.001