Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease

被引:106
作者
Achenbach, Stephan [1 ]
Ropers, Ulrike [1 ]
Kuettner, Axel [2 ]
Anders, Katharina [2 ]
Pflederer, Tobias [1 ]
Komatsu, Sei [1 ]
Bautz, Werner [2 ]
Daniel, Werner G. [1 ]
Ropers, Dieter [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
关键词
D O I
10.1016/j.jcmg.2007.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to analyze the influence of a systematic approach to lower heart rate for coronary computed tomography (CT) angiography on diagnostic accuracy of 64-slice single-and dual-source CT. BACKGROUND Coronary CT angiography is often impaired by motion artifacts, so that routine lowering of heart rate is usually recommended. This is often conceived as a major limitation of the technique. It is expected that higher temporal resolution, such as with dual-source 64-slice CT, would allow diagnostic imaging even without systematic pre-treatment for lowering the heart rate. METHODS Two hundred patients with suspected coronary artery disease were first randomized to either 64-slice single-source CT (n = 100) or dual-source CT (n = 100) for contrast-enhanced coronary artery evaluation. In each group, patients were further randomized to either receive systematic heart rate control (oral and intravenous beta-blockade for a target heart rate <= 60 beats/min) or receive no premedication. Evaluability of datasets and diagnostic accuracy were compared between groups against the results obtained from invasive angiography. RESULTS Systematic pre-treatment lowered heart rate during CT coronary angiography by 10 beats/min. Heart rate control significantly improved evaluability in single-source CT (93% vs. 69% on a per-patient basis, p = 0.005), whereas it did not in dual-source CT (96% vs. 98%). In evaluable patients, sensitivity to detect the presence of at least 1 coronary stenosis by single-source CT was 86% and 79%, respectively, with and without heart rate control (p = NS). For dual-source CT, it was 100% and 95%, respectively (p = NS). The rate of correctly classified patients, defined as evaluable and correct classification as to the presence or absence of at least 1 coronary artery stenosis, was significantly improved by heart rate control in single-source CT (78% vs. 57%, p = 0.04), whereas there was no such influence in dual-source CT (87% vs. 93%). CONCLUSIONS Systematic heart rate control significantly improves image quality for coronary visualization by 64-slice single-source CT, whereas image quality and diagnostic accuracy remain unaffected in dual-source CT angiography. Improved temporal resolution obviates the need for heart rate control. (J Am Coll Cardiol Img 2008; 1: 177-86) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:177 / 186
页数:10
相关论文
共 24 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Computed tomography coronary angiography [J].
Achenbach, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :1919-1928
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]  
BRODOEFEL H, 2007, EUR J RADIOL
[5]   Multisegment and halfscan reconstruction of 16-slice computed tomography for assessment of regional and global left ventricular myocardial function [J].
Dewey, M ;
Müller, M ;
Teige, F ;
Schnapauff, D ;
Schink, T ;
Hamm, B ;
Lembcke, A .
INVESTIGATIVE RADIOLOGY, 2006, 41 (04) :400-409
[6]   Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses [J].
Dewey, M ;
Laule, M ;
Krug, L ;
Schnapauff, D ;
Rogalla, P ;
Rutsch, WF ;
Hamm, B ;
Lembcke, A .
INVESTIGATIVE RADIOLOGY, 2004, 39 (04) :223-229
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   Computed tomographic angiography of the coronary arteries: Techniques and applications [J].
Gerber, TC ;
Breen, JF ;
Kuzo, RS ;
Kantor, B ;
Williamson, EE ;
Safford, RE ;
Morin, RL .
SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (01) :42-55
[9]   Non-invasive detection of coronary artery disease in patients with left bundle branch block using 64-slice computed tomography [J].
Ghostine, Said ;
Caussin, Christophe ;
Daoud, Beatrice ;
Habis, Michel ;
Perrier, Eric ;
Pesenti-Rossi, David ;
Sigal-Cinqualbre, Anne ;
Angel, Claude-Yves ;
Lancelin, Bernard ;
Capderou, Andre ;
Paul, Jean-Francois .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :1929-1934
[10]   Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography - A meta-analysis [J].
Hamon, Michele ;
Biondi-Zoccai, Giuseppe G. L. ;
Malagutti, Patrizia ;
Agostoni, Pierfrancesco ;
Morello, Remy ;
Valgimigli, Marco ;
Hamon, Martial .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (09) :1896-1910