Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience

被引:285
作者
Achenbach, S
Ropers, D
Kuettner, A
Flohr, T
Ohnesorge, B
Bruder, H
Theessen, H
Karakaya, M
Daniel, WG
Bautz, W
Kalender, WA
Anders, K
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
[4] Siemens Med Solut, Forchheim, Germany
[5] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
computed tomography; coronary arteries; coronary angiography;
D O I
10.1016/j.ejrad.2005.12.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multi-detector computed tomography (CT) scanners, by virtue of their high temporal and spatial resolution, permit imaging of the coronary arteries. However, motion artifacts, especially in patients with higher heart rates, can impair image quality. We thus evaluated the performance of a new dual-source CT (DSCT) with a heart rate independent temporal resolution of 83 ms for the visualization of the coronary arteries in 14 consecutive patients. Methods: Fourteen patients (mean age 61 years, mean heart rate 71 min(-1)) were studied by DSCT. The system combines two arrays of an X-ray tube plus detector (64 slices) mounted on a single gantry at an angle of 90 degrees With a rotation speed of 330 ms, a temporal resolution of 83 ms (one-quarter rotation) can be achieved independent of heart rate. For data acquisition, intraveous contrast agent was injected at a rate of 5 ml/s. Images were reconstructed with 0.75 slice thickness and 0.5 mm increment. The data sets were evaluated concerning visibility of the coronary arteries and occurrence of motion artifact. Results: Visualization of the coronary arteries was successful in all patients. Most frequently, image reconstruction at 70% of the cardiac cycle provided for optimal image quality (50% of patients). Of a total of 226 coronary artery segments, 222 (98%) were visualized free of motion artifact. In summary, DSCT constitutes a promising new concept for cardiac CT. High and heart rate independent temporal resolution permits imaging of the coronary arteries without motion artifacts in a substantially increased number of patients as compared to earlier scanner generations. Larger and appropriately designed studies will need to determine the method's accuracy for detection of coronary artery stenoses. (C) 2005 Published by Elsevier Ireland Ltd.
引用
收藏
页码:331 / 335
页数:5
相关论文
共 16 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [3] Becker CR, 2000, RADIOLOGE, V40, P118, DOI 10.1007/s001170050019
  • [4] Performance evaluation of a 64-slice CT system with z-flying focal spot
    Flohr, T
    Stierstorfer, K
    Raupach, R
    Ulzheimer, S
    Bruder, H
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12): : 1803 - 1810
  • [5] Multi-detector row CT systems and image-reconstruction techniques
    Flohr, TG
    Schaller, S
    Stierstorfer, K
    Bruder, H
    Ohnesorge, BM
    Schoepf, UJ
    [J]. RADIOLOGY, 2005, 235 (03) : 756 - 773
  • [6] Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot
    Flohr, TG
    Stierstorfer, K
    Ulzheimer, S
    Bruder, H
    Primak, AN
    McCollough, CH
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2536 - 2547
  • [7] Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection
    Giesler, T
    Baum, U
    Ropers, D
    Ulzheimer, S
    Wenkel, E
    Mennicke, M
    Bautz, W
    Kalender, WA
    Daniel, WG
    Achenbach, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) : 911 - 916
  • [8] Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate
    Hoffmann, MHK
    Shi, HS
    Manzke, R
    Schmid, FT
    De Vries, L
    Grass, M
    Brambs, HR
    Aschoff, AJ
    [J]. RADIOLOGY, 2005, 234 (01) : 86 - 97
  • [9] Noninvasive coronary angiography with multislice computed tomography
    Hoffmann, MHK
    Shi, HS
    Schmitz, BL
    Schmid, FT
    Lieberknecht, ML
    Schulze, R
    Ludwig, B
    Kroschel, U
    Jahnke, N
    Haerer, W
    Brambs, HJ
    Aschoff, AJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20): : 2471 - 2478
  • [10] ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    Kachelriess, M
    Ulzheimer, S
    Kalender, WA
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1881 - 1902