Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection

被引:225
作者
Giesler, T
Baum, U
Ropers, D
Ulzheimer, S
Wenkel, E
Mennicke, M
Bautz, W
Kalender, WA
Daniel, WG
Achenbach, S
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med 2, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
D O I
10.2214/ajr.179.4.1790911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Although multidetector CT (MDCT) with retrospectively ECG-gated image reconstruction has been shown to permit noninvasive visualization of the coronary arteries, the 125-250 msec required for image acquisition frequently causes motion artifacts. We investigated the influence of a patient's heart rate on the presence of motion artifacts and on accuracy of stenosis detection on contrast-enhanced MDCT. MATERIALS AND METHODS. In 100 patients, MDCT was performed, and ECG-gated cross-sectional images were retrospectively reconstructed. From the 10 data sets obtained for each patient (reconstructed at 0-90% of the cardiac cycle in increments of 10%), we. chose the best data set for every coronary artery. The images of the arteries were evaluated for occurrence of artifacts and the presence of high-grade stenosis (diameter reduction exceeding 70%) or occlusions. MDCT results were compared with coronary angiographic findings. RESULTS. Of the 400 coronary arteries, 115 (29%) could not be evaluated because of motion artifacts (n = 84) or other reasons (n = 31). Overall, 51 (49%) of 104 stenoses were revealed on MDCT. For detecting stenosis in those arteries that we could evaluate, MDCT had a sensitivity of 91% (51 of 56 stenoses detected) and a specificity of 89%. As the heart rate increased, the number of arteries that could be evaluated decreased, and overall sensitivity for stenosis detection decreased from 62% (heart rate less than or equal to 70 beats per minute) to 33% (heart rate > 70 beats per minute). CONCLUSION. MDCT can reveal coronary stenoses, but the usefulness of MDCT as an aid in accurately evaluating stenoses decreases as a patient's heart rate increases.
引用
收藏
页码:911 / 916
页数:6
相关论文
共 22 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[4]   Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating [J].
Becker, CR ;
Knez, A ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :423-424
[5]   INVIVO VALIDATION OF ONLINE AND OFF-LINE GEOMETRIC CORONARY MEASUREMENTS USING INSERTION OF STENOSIS PHANTOMS IN PORCINE CORONARY-ARTERIES [J].
HAASE, J ;
DIMARIO, C ;
SLAGER, CJ ;
VANDERGIESSEN, WJ ;
DENBOER, A ;
DEFEYTER, PJ ;
REIBER, JHC ;
VERDOUW, PD ;
SERRUYS, PW .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 27 (01) :16-27
[6]   Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification [J].
Hofman, MBM ;
Wickline, SA ;
Lorenz, CH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :568-576
[7]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[8]   ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart [J].
Kachelriess, M ;
Ulzheimer, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (08) :1881-1902
[9]   Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses [J].
Knez, A ;
Becker, CR ;
Leber, A ;
Ohnesorge, B ;
Becker, A ;
White, C ;
Haberl, R ;
Reiser, MF ;
Steinbeck, G .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1191-+
[10]  
Knez A, 2000, CIRCULATION, V102, P411