ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality

被引:209
作者
Hong, C
Becker, CR
Huber, A
Schoepf, UJ
Ohnesorge, B
Knez, A
Brüning, R
Reiser, MF
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Div Cardiol, D-81377 Munich, Germany
[3] Siemens Med Syst Inc, Forchheim, Germany
[4] Tongji Med Univ, Dept Radiol, Tongji, Peoples R China
关键词
coronary vessels; CT; heart;
D O I
10.1148/radiol.2203010055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effectiveness of electrocardiographically (ECG)-gated retrospective image reconstruction for multi-detector row computed tomographic (CT) coronary angiography in reducing cardiac motion artifacts and to evaluate the influence of heart rate on cardiac image quality. MATERIALS AND METHODS: Sixty-five patients with different heart rates underwent coronary CT angiography. Raw helical CT data and ECG tracings were combined to retrospectively reconstruct at the defined consecutive z position with a temporal resolution of 250 msec per section. The starting points of the reconstruction were chosen between 30% and 80% of the R-R intervals. The relationships between heart rate, trigger delay, and image quality were analyzed. RESULTS: Optimal image quality was achieved with a 50% trigger delay for the right coronary artery and 60% for the left circumflex coronary artery. Optimal image quality for the left anterior descending coronary artery was equally obtained at 50% and 60% triggering. A significant negative correlation was observed between heart rate and image quality (P < .05). The best image quality was achieved when the heart rate was less than 74.5 beats per minute. CONCLUSION: To achieve high image quality, the heart rate should be sufficiently slow. Selection of appropriate trigger delays and a decreasing heart rate are effective to reduce cardiac motion artifacts.
引用
收藏
页码:712 / 717
页数:6
相关论文
共 25 条
[1]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   EFFECTS OF BIOLOGICAL MOTION ON CT RESOLUTION [J].
ALFIDI, RJ ;
MACINTYRE, WJ ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 127 (01) :11-15
[4]   Predictive value of electron beam computed tomography of the coronary arteries - 19-month follow-up of 1173 asymptomatic subjects [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
LledoPerez, A ;
Sherman, S ;
Lerner, C ;
Guerci, AD .
CIRCULATION, 1996, 93 (11) :1951-1953
[5]  
Austen WG, 1975, CIRCULATION S4, V51, P5
[6]  
BASKIN KM, 1995, RADIOLOGY, V197, P182
[7]  
Becker C, 2000, AM J ROENTGENOL, V174, P1
[8]   Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating [J].
Becker, CR ;
Knez, A ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :423-424
[9]   Detection and quantification of coronary artery calcification with electron-beam and conventional CT [J].
Becker, CR ;
Knez, A ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
EUROPEAN RADIOLOGY, 1999, 9 (04) :620-624
[10]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298