Noninvasive coronary angiography with multislice computed tomography

被引:376
作者
Hoffmann, MHK
Shi, HS
Schmitz, BL
Schmid, FT
Lieberknecht, ML
Schulze, R
Ludwig, B
Kroschel, U
Jahnke, N
Haerer, W
Brambs, HJ
Aschoff, AJ
机构
[1] Univ Hosp, Dept Diagnost Radiol, D-89070 Ulm, Germany
[2] Ctr Heart, Dept Cardiol, Ulm, Germany
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2005年 / 293卷 / 20期
关键词
D O I
10.1001/jama.293.20.2471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Multislice computed tomography(MSCT) has recently evolved as a modality for noninvasive coronary imaging. Objective To assess the accuracy and robustness of MSCT vs the criterion standard of invasive coronary angiography for detection of obstructive coronary artery disease. Design, Setting, and Patients Prospective, single-center study conducted in a referral center setting in Germany and enrolling 103 consecutive patients (mean age, 61.5 [SD, 9.7] years) from November 2003-August 2004 who were undergoing both invasive coronary angiography and MSCT using a scanner with 16 detector rows. Main Outcome Measures Blinded results for both modalities compared using the patient as the primary unit of analysis, with supplementary segment- and vessel-based analyses. Results One thousand three hundred eighty-four segments ( ≥ 1.5 mm diameter) were identified by invasive coronary angiography; nondiagnostic image quality of MSCT was identified for only 88 (6.4%) of these segments, mainly due to faster heart rates. Compared with invasive coronary angiography for detection of significant lesions (>50% stenosis), segment-based sensitivity, specificity, and positive and negative predictive values of MSCT were 95%, 98%, 87%, and 99%, respectively. Quantitative comparison of MSCT and invasive coronary angiography showed good correlation (r=0.87, P<.001), with MSCT systematically measuring greater-percentage stenoses (bias, + 12%). In the patient-based analysis, the area under the receiver operating characteristic curve was 0.97 (95% confidence interval, 0.90-1.00), indicating high discriminative power to identify patients who might be candidates for revascularization (>50% left main artery stenosis and/or >70% stenosis in any other epicardial vessel). Threshold optimization allowed either detection of these patients with 100% sensitivity at a reasonable false-positive rate (specificity, 76.5%; MSCT stenosis, >66%) or optimization of both the sensitivity and specificity (>90%; MSCT stenosis, >76%). Conclusions Multislice computed tomography provides high accuracy for noninvasive detection of suspected obstructive coronary artery disease. This promising technology has potential to complement diagnostic invasive coronary angiography in routine clinical care.
引用
收藏
页码:2471 / 2478
页数:8
相关论文
共 32 条
  • [1] Editorial comment - Detection of coronary stenoses by multidetector computed tomography: It's all about resolution
    Achenbach, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 840 - 841
  • [2] Austen W G, 1975, Circulation, V51, P5
  • [3] American College of Cardiology/Society for Cardiac Angiography and Interventions clinical expert consensus document on Cardiac Catheterization Laboratory standards - A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    Bashore, TM
    Bates, ER
    Berger, PB
    Clark, DA
    Cusma, JT
    Dehmer, GJ
    Kern, MJ
    Laskey, WK
    O'Laughlin, MP
    Oesterle, S
    Popma, JJ
    O'Rourke, RA
    Abrams, J
    Bates, ER
    Brodie, BR
    Douglas, PS
    Gregoratos, G
    Hlatky, MA
    Hochman, JS
    Kaul, S
    Tracy, CM
    Waters, DD
    Winters, WL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) : 2170 - 2214
  • [4] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [5] Noninvasive multi-slice computed tomography coronary angiography - An emerging clinical modality
    de Feyter, PJ
    Nieman, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) : 1238 - 1240
  • [6] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [7] ACC/AHA 2002 guideline update for exercise testing: Summary article - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines)
    Gibbons, RJ
    Balady, GJ
    Bricker, JT
    Chaitman, BR
    Fletcher, GF
    Froelicher, VF
    Mark, DB
    McCallister, BD
    Mooss, AN
    O'Reilly, MG
    Winters, WL
    Antman, EM
    Alpert, JS
    Faxon, DP
    Fuster, V
    Gregoratos, G
    Hiratzka, LF
    Jacobs, AK
    Russell, RO
    Smith, SC
    [J]. CIRCULATION, 2002, 106 (14) : 1883 - 1892
  • [8] Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection
    Giesler, T
    Baum, U
    Ropers, D
    Ulzheimer, S
    Wenkel, E
    Mennicke, M
    Bautz, W
    Kalender, WA
    Daniel, WG
    Achenbach, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) : 911 - 916
  • [9] Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient
    Gönen, M
    Panageas, KS
    Larson, SM
    [J]. RADIOLOGY, 2001, 221 (03) : 763 - 767
  • [10] Helical cardiac cone beam reconstruction using retrospective ECG gating
    Grass, M
    Manzke, R
    Nielsen, T
    Koken, P
    Proksa, R
    Natanzon, M
    Shechter, G