Helical cardiac cone beam reconstruction using retrospective ECG gating

被引:88
作者
Grass, M
Manzke, R
Nielsen, T
Koken, P
Proksa, R
Natanzon, M
Shechter, G
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
[2] Philips Med Syst, Haifa, Israel
关键词
D O I
10.1088/0031-9155/48/18/308
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In modem computer tomography (CT) systems, the fast rotating gantry and the increased detector width enable 3D imaging of the heart. Cardiac volume CT has a high potential for non-invasive coronary angiography with high spatial resolution and short scan time. Due to the increased detector width, true cone beam reconstruction methods are needed instead of adapted 2D reconstruction schemes. In this paper, the extended cardiac reconstruction method is introduced. It integrates the idea of retrospectively gated cardiac reconstruction for helical data acquisition into a cone beam reconstruction framework. It leads to an efficient and flexible algorithmic scheme for the reconstruction of single- and multi-phase cardiac volume datasets. The method automatically adapts the number of cardiac cycles used for the reconstruction. The cone beam geometry is fully taken into account during the reconstruction process. Within this paper, results are presented on patient datasets which have been acquired using a 16-slice cone beam CT system.
引用
收藏
页码:3069 / 3084
页数:16
相关论文
共 21 条
[1]  
BRUDER H, 2001, P 3D 01 C PAC GROV C
[2]  
CHANDRA S, 2000, 2 ANN CARD CT C HEID
[3]  
Cline H, 2000, Circulation, V102, P1589
[4]  
HOFFMANN M, 2003, UNPUB RADIOLOGY
[5]   Multislice helical CT: Image temporal resolution [J].
Hu, H ;
Pan, TS ;
Shen, Y .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) :384-390
[6]  
Kachelriess M, 2000, IEEE T MED IMAGING, V19, P888, DOI 10.1109/42.887837
[7]   ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart [J].
Kachelriess, M ;
Ulzheimer, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (08) :1881-1902
[8]   Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Kalender, WA .
MEDICAL PHYSICS, 1998, 25 (12) :2417-2431
[9]   Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Sennst, DA ;
Maxlmoser, W ;
Kalender, WA .
MEDICAL PHYSICS, 2002, 29 (07) :1489-1503
[10]   Theoretically exact filtered backprojection-type inversion algorithm for spiral CT [J].
Katsevich, A .