Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate

被引:215
作者
Hoffmann, MHK
Shi, HS
Manzke, R
Schmid, FT
De Vries, L
Grass, M
Brambs, HR
Aschoff, AJ
机构
[1] Univ Hosp Ulm, Dept Diagnost Radiol, D-89070 Ulm, Germany
[2] Philips Med Syst, Cleveland, OH USA
[3] Philips Res Labs, Hamburg, Germany
关键词
D O I
10.1148/radiol.2341031408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effect of heart rate on the quality of coronary angiograms obtained with 16-detector row computed tomography (CT) by using temporally enhanced three-dimensional (3D) approaches. MATERIALS AND METHODS: The local ethics committee approved the study, and informed consent was obtained from all patients. Fifty patients underwent coronary CT angiography (heart rate range, 45-103 beats per minute). Raw data from helical CT and electrocardiography (ECG) were saved in a combined data set. Retrospectively ECG-gated images were reconstructed at preselected phases (50% and 80%) of the cardiac cycle. A 3D voxel-based approach with cardiac phase weighting was used for reconstruction. Testing for correlation between heart rate, cardiac phase reconstruction window, and image quality was performed with Kruskal-Wallis analysis. Image quality (freedom from cardiac motion-related artifacts) was referenced against findings at conventional angiography in a secondary evaluation step. Regression analysis was performed to calculate heart rate thresholds for future p-blocker application. RESULTS: A significant negative correlation was observed between heart rate and image quality (r = 0.80, P <.001). Motion artifact-free images were available for 44 (88%) patients and were achieved consistently at a heart rate of 80 or fewer beats per minute (n = 39). Best image quality was achieved at 75 or fewer beats per minute. Segmental analysis revealed that 97% of arterial segments (diameter >= 1.5 mm according to conventional angiography) were assessable at 80 or fewer beats per minute. Premature ventricular contractions and rate-contained arrhythmia did not impede diagnostic assessment of the coronary arteries in 10 (83%) of the 12 patients affected. CONCLUSION: Motion-free coronary angiograms can be obtained consistently with 16-detector row CT scanners and adaptive multicyclic reconstruction algorithms in patients with heart rates of less than 80 beats per minute.
引用
收藏
页码:86 / 97
页数:12
相关论文
共 27 条
  • [1] Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries
    Achenbach, S
    Moshage, W
    Ropers, D
    Bachmann, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) : 895 - 899
  • [2] Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography
    Achenbach, S
    Giesler, T
    Ropers, D
    Ulzheimer, S
    Anders, K
    Wenkel, E
    Pohle, K
    Kachelriess, M
    Derlien, H
    Kalender, WA
    Daniel, WG
    Bautz, W
    Baum, U
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (02) : 119 - 128
  • [3] In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    Achenbach, S
    Ropers, D
    Holle, J
    Muschiol, G
    Daniel, WG
    Moshage, W
    [J]. RADIOLOGY, 2000, 216 (02) : 457 - 463
  • [4] American College of Cardiology/Society for Cardiac Angiography and Interventions clinical expert consensus document on Cardiac Catheterization Laboratory standards - A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    Bashore, TM
    Bates, ER
    Berger, PB
    Clark, DA
    Cusma, JT
    Dehmer, GJ
    Kern, MJ
    Laskey, WK
    O'Laughlin, MP
    Oesterle, S
    Popma, JJ
    O'Rourke, RA
    Abrams, J
    Bates, ER
    Brodie, BR
    Douglas, PS
    Gregoratos, G
    Hlatky, MA
    Hochman, JS
    Kaul, S
    Tracy, CM
    Waters, DD
    Winters, WL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) : 2170 - 2214
  • [5] CHANGES IN DIASTOLIC TIME WITH VARIOUS PHARMACOLOGIC AGENTS - IMPLICATION FOR MYOCARDIAL PERFUSION
    BOUDOULAS, H
    RITTGERS, SE
    LEWIS, RP
    LEIER, CV
    WEISSLER, AM
    [J]. CIRCULATION, 1979, 60 (01) : 164 - 169
  • [6] Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study
    Budoff, MJ
    Georgiou, D
    Brody, A
    Agatston, AS
    Kennedy, J
    Wolfkiel, C
    Stanford, W
    Shields, P
    Lewis, RJ
    Janowitz, WR
    Rich, S
    Brundage, BH
    [J]. CIRCULATION, 1996, 93 (05) : 898 - 904
  • [7] Helical cardiac cone beam reconstruction using retrospective ECG gating
    Grass, M
    Manzke, R
    Nielsen, T
    Koken, P
    Proksa, R
    Natanzon, M
    Shechter, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (18) : 3069 - 3084
  • [8] Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality
    Herzog, C
    Abolmaali, N
    Balzer, JO
    Baunach, S
    Ackermann, H
    Dogan, S
    Britten, MB
    Vogl, TJ
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2670 - 2678
  • [9] Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time:: first experiences
    Heuschmid, M
    Küttner, A
    Flohr, T
    Wildberger, JE
    Lell, M
    Kopp, AF
    Schröder, S
    Baum, U
    Schaller, S
    Hartung, A
    Ohnesorge, B
    Claussen, CD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 721 - 724
  • [10] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717