Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography

被引:94
作者
Achenbach, S
Giesler, T
Ropers, D
Ulzheimer, S
Anders, K
Wenkel, E
Pohle, K
Kachelriess, M
Derlien, H
Kalender, WA
Daniel, WG
Bautz, W
Baum, U
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med 2, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
electron beam tomography; multislice spiral CT; computed tomography; coronary arteries;
D O I
10.1097/00004424-200302000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization. MATERIALS AND METHODS. Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured. RESULTS. Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P < 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P < 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography. CONCLUSIONS. EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 35 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography
    Achenbach, S
    Moshage, W
    Ropers, D
    Bachmann, K
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01): : 1 - 7
  • [3] Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries
    Achenbach, S
    Moshage, W
    Ropers, D
    Bachmann, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) : 895 - 899
  • [4] Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions
    Achenbach, S
    Moshage, W
    Ropers, D
    Nossen, J
    Daniel, WG
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) : 1964 - 1971
  • [5] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [6] In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    Achenbach, S
    Ropers, D
    Holle, J
    Muschiol, G
    Daniel, WG
    Moshage, W
    [J]. RADIOLOGY, 2000, 216 (02) : 457 - 463
  • [7] Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
  • [8] Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating
    Becker, CR
    Knez, A
    Ohnesorge, B
    Schoepf, UJ
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 423 - 424
  • [9] Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography
    Budoff, MJ
    Oudiz, RJ
    Zalace, CP
    Bakhsheshi, H
    Goldberg, SL
    French, WJ
    Rami, TG
    Brundage, BH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) : 840 - 845
  • [10] Evaluation of electron beam CT coronary angiography in healthy subjects
    Chernoff, DM
    Ritchie, CJ
    Higgins, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 93 - 99