Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography

被引:94
作者
Achenbach, S
Giesler, T
Ropers, D
Ulzheimer, S
Anders, K
Wenkel, E
Pohle, K
Kachelriess, M
Derlien, H
Kalender, WA
Daniel, WG
Bautz, W
Baum, U
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med 2, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
electron beam tomography; multislice spiral CT; computed tomography; coronary arteries;
D O I
10.1097/00004424-200302000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization. MATERIALS AND METHODS. Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured. RESULTS. Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P < 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P < 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography. CONCLUSIONS. EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 35 条
[31]   Intravenous electron-beam computed tomographic coronary angiography for segmental analysis of coronary artery stenoses [J].
Schmermund, A ;
Rensing, BJ ;
Sheedy, PF ;
Bell, MR ;
Rumberger, JA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (07) :1547-1554
[32]   Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography [J].
Schroeder, S ;
Kopp, AF ;
Baumbach, A ;
Meisner, C ;
Kuettner, A ;
Georg, C ;
Ohnesorge, B ;
Herdeg, C ;
Claussen, CD ;
Karsch, KR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1430-1435
[33]   Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography - Experience in 94 patients [J].
Schroeder, S ;
Kopp, AF ;
Kuettner, A ;
Burgstahler, C ;
Herdeg, C ;
Heuschmid, M ;
Baumbach, A ;
Claussen, CD ;
Karsch, KR ;
Seipel, L .
CLINICAL IMAGING, 2002, 26 (02) :106-111
[34]   Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography [J].
Stuber, M ;
Botnar, RM ;
Danias, PG ;
Sodickson, DK ;
Kissinger, KV ;
Van Cauteren, M ;
De Becker, J ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) :524-531
[35]   Breath-hold coronary MR angiography with volume targeted imaging [J].
Wielopolski, PA ;
van Geuns, RJM ;
de Feyter, PJ ;
Oudkerk, M .
RADIOLOGY, 1998, 209 (01) :209-219