Performance evaluation of a 64-slice CT system with z-flying focal spot

被引:205
作者
Flohr, T
Stierstorfer, K
Raupach, R
Ulzheimer, S
Bruder, H
机构
[1] CTE PA, Comp Tomog, Siemens Med Solut, D-91301 Forchheim, Germany
[2] Univ Tubingen, Abt Radiol Diagnost, Tubingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2004年 / 176卷 / 12期
关键词
16-slice CT systems; spatial and temporal resolution; z-flying focal spot; ECG-gated reconstruction;
D O I
10.1055/s-2004-813717
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp(TM)). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG-gated reconstruction.
引用
收藏
页码:1803 / 1810
页数:8
相关论文
共 22 条
  • [1] Ertl-Wagner B, 2002, RADIOLOGE, V42, P728, DOI 10.1007/s00117-002-0786-2
  • [2] Image reconstruction and image quality evaluation for a 16-slice CT scanner
    Flohr, T
    Stierstorfer, K
    Bruder, H
    Simon, J
    Polacin, A
    Schaller, S
    [J]. MEDICAL PHYSICS, 2003, 30 (05) : 832 - 845
  • [3] New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning
    Flohr, T
    Stierstorfer, K
    Bruder, H
    Simon, J
    Schaller, S
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07): : 839 - 845
  • [4] New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging
    Flohr, T
    Bruder, H
    Stierstorfer, K
    Simon, J
    Schaller, S
    Ohnesorge, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1022 - 1027
  • [5] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [6] FLOHR T, 2003, 89 SCI ASS ANN M RSN, P567
  • [7] Analytical models for multi-slice helical CT performance parameters
    Hsieh, J
    [J]. MEDICAL PHYSICS, 2003, 30 (02) : 169 - 178
  • [8] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    [J]. MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [9] Advanced single-slice rebinning in cone-beam spiral CT
    Kachelriess, M
    Schaller, S
    Kalender, WA
    [J]. MEDICAL PHYSICS, 2000, 27 (04) : 754 - 772
  • [10] Subsecond multi-slice computed tomography: basics and applications
    Klingenbeck-Regn, K
    Schaller, S
    Flohr, T
    Ohnesorge, B
    Kopp, AF
    Baum, U
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) : 110 - 124