New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging

被引:116
作者
Flohr, T [1 ]
Bruder, H [1 ]
Stierstorfer, K [1 ]
Simon, J [1 ]
Schaller, S [1 ]
Ohnesorge, B [1 ]
机构
[1] Siemens Med Solut CTC CF, D-91302 Forchheim, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 08期
关键词
multislice CT; cardiac CT; cardiac imaging;
D O I
10.1055/s-2002-32930
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite all promising advances, some challenges remain for ECG-gated multislice CT examinations of the heart and the coronary arteries with current 4-slice detectors: adequate visualization of stents and severely calcified coronary arteries, examination of patients with higher heart rates and patients, who cannot adequately hold their breath for at least 30 sec. The new generation of multislice CT systems offering simultaneous acquisition of up to 16 sub-millimeter slices and gantry rotation times shorter than 0.5 sec has the potential to overcome these limitations. We describe the technical principles of cardiac scanning with a state-of-the-art 16-slice CT equipment (SOMATOM Sensation 16, Siemens AG, Forchheim, Germany). We discuss an extension of the Adaptive Cardio Volume (ACV) reconstruction approach for ECG-gated multislice spiral CT. We show the impact of reduced gantry rotation time (0.42 sec) on temporal resolution, and we demonstrate the influence of slice width on the visualization of stents and plaques. Deviating from general purpose applications a cone-correction is not required for cardiac scanning with 16-slice CT systems. In addition to the absolute improvement, the temporal resolution shows a different dependence on the patient's heart rate for 0.42 sec rotation time, reaching its optimum (105 msec) at 81 BPM. This has the potential to expand the range of heart rates accessible to routine clinical examinations. Owing to sub-millimeter slice width and optimized in-plane resolution characteristics, visualization of stents and severe calcifications in coronary arteries is significantly improved. Clinical experience will be needed to fully evaluate the potential of 16-slice technology for cardiac imaging.
引用
收藏
页码:1022 / 1027
页数:6
相关论文
共 17 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating
    Becker, CR
    Knez, A
    Ohnesorge, B
    Schoepf, UJ
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 423 - 424
  • [3] BRUDER H, 2001, 6 INT M FULL 3 DIM I
  • [4] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [5] FLOHR T, 2000, 86 SCI ASS ANN M R P, V217, P438
  • [6] FLOHR T, 2001, 87 SCI ASS ANN M RSN, P457
  • [7] The optimal time point in RR interval for data reconstructioin to visualize coronary arteries by multi slice computed tomography.
    Georg, C
    Kopp, A
    Schröder, S
    Küttner, A
    Ohnesorge, B
    Martensen, J
    Clausen, CD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (06): : 536 - 541
  • [8] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [9] ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    Kachelriess, M
    Ulzheimer, S
    Kalender, WA
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1881 - 1902
  • [10] Knez A, 2000, CIRCULATION, V101, pE221