The optimal time point in RR interval for data reconstructioin to visualize coronary arteries by multi slice computed tomography.

被引:28
作者
Georg, C
Kopp, A
Schröder, S
Küttner, A
Ohnesorge, B
Martensen, J
Clausen, CD
机构
[1] Univ Tubingen, Radiol Klin, Abt Radiol Diagnost, D-72076 Tubingen, Germany
[2] Univ Tubingen, Med Klin, Abt Kardiol 3, D-7400 Tubingen, Germany
[3] Siemens AG, Med Techn, Forchheim, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2001年 / 173卷 / 06期
关键词
multislice CT; spiral CT; cardio CT; retrospective ECG gating;
D O I
10.1055/s-2001-14983
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Multislice spiral CT is a newly developed technology that allows the non-invasive detection of coronary stenoses and plaques. The acquired raw data are reconstructed at a given time point in the RR interval of the heart cycle. Thus, determination of this time point is a key factor for picture quality and for reliable diagnostic results. This study was performed to investigate the optimal time point for reconstruction within the RR interval. Materials and Methods: The coronary arteries of 13 patients were examined with CT. Raw data were reconstructed 250, 350, 450 and 550 ms before the following R wave (absolute reverse retrospective ECG gating) for each patient. Data were then analyzed with a volume rendering mode on a SIEMENS 3 D-Virtuoso workstation. A total of 91 segments (segments 1 and 2 of the RCA, segments 5, 6, 7 and proximal and distal parts of segment 11) were assessed and image quality was classified. Results: Visualization of the left main coronary artery was of a good quality at all time points, segments 6 and 7 of the LAD as well as the proximal and distal parts of segment 11 of the RCX had the best quality at 450 ms absolute reverse retrospective ECG gating. The segments 1 and 2 of the RCA were of best quality 550% ms absolute reverse to the R peak. Conclusions: Classification of image quality of coronary artery CT scans after retrospectively ECG gated reconstruction is highly determined by the time point of reconstruction in the heart cycle. The optimization of this time point increases diagnostic accuracy and helps to avoid misinterpretation due to image artifacts.
引用
收藏
页码:536 / 541
页数:6
相关论文
共 14 条
[1]   Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating [J].
Becker, CR ;
Knez, A ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :423-424
[2]   High temporal resolution volume heart imaging with multirow computed tomography [J].
Bruder, H ;
Schaller, S ;
Ohnesorge, B ;
Mertelmeier, T .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :420-432
[3]   Coronary artery bypass grafts:: Improved electron-beam tomography by prolonging breath holds with preoxygenation [J].
Enzweiler, CNH ;
Kivelitz, DE ;
Wiese, TH ;
Taupitz, M ;
Höhn, S ;
Borges, AC ;
Pietsch, L ;
Dohmen, P ;
Baumann, G ;
Hamm, B .
RADIOLOGY, 2000, 217 (01) :278-283
[4]   ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart [J].
Kachelriess, M ;
Ulzheimer, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (08) :1881-1902
[5]   Cardiac multidetector-row CT:: Retrospectively ECG-gated spiral with optimized temporal and spatial resolution:: First clinical results. [J].
Kopp, AF ;
Ohnesorge, B ;
Flohr, T ;
Georg, C ;
Schröder, S ;
Küttner, A ;
Martensen, J ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (05) :429-435
[6]  
KOPP AF, 1999, 1 INT S MULT ROW CT
[7]   Coronary artery motion in electron beam tomography [J].
Mao, SS ;
Lu, B ;
Oudiz, RJ ;
Bakhsheshi, H ;
Liu, SCK ;
Budoff, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) :253-258
[8]   Flow profiles in the left anterior descending and the right coronary artery assessed by MR velocity quantification: Effects of through-plane and in-plane motion of the heart [J].
Marcus, JT ;
Smeenk, HG ;
Kuijer, JPA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (04) :567-576
[9]   CORONARY-ARTERY STENOSES - 3-DIMENSIONAL IMAGING WITH ELECTROCARDIOGRAPHICALLY TRIGGERED, CONTRAST AGENT-ENHANCED, ELECTRON-BEAM CT [J].
MOSHAGE, WEL ;
ACHENBACH, S ;
SEESE, B ;
BACHMANN, K ;
KIRCHGEORG, M .
RADIOLOGY, 1995, 196 (03) :707-714
[10]  
Ohnesorge B, 1999, RADIOLOGE, V39, P923, DOI 10.1007/s001170050583