Flow profiles in the left anterior descending and the right coronary artery assessed by MR velocity quantification: Effects of through-plane and in-plane motion of the heart

被引:61
作者
Marcus, JT
Smeenk, HG
Kuijer, JPA
机构
[1] Vrije Univ Amsterdam, Dept Clin Phys & Informat, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Inst Cardiovasc Res, Dept Cardiol, Amsterdam, Netherlands
[3] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
关键词
magnetic resonance imaging; techniques; heart anatomy; arteries; coronary; occlusion;
D O I
10.1097/00004728-199907000-00017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to compare the temporal profiles of volume flow in the left anterior descending artery (LAD) and the right coronary artery (RCA) and to assess the effect of through-plane and in-plane myocardial motion. Method: In eight healthy volunteers, MR phase-difference velocity quantification was applied with prospective ECG triggering, pixel size of 1.16 x 0.98 mm(2) (LAD) or 1.25 x 0.98 mm(2) (RCA), velocity sensitivity of 40 cm/s, and data acquisition time window of 64 ms for LAD (3 k, lines per heartbeat) and 24 ms for RCA. In-plane motion was measured from the magnitude images. Results: In the LAD, systolic peak and mean flow values were 0.94 +/- 0.28 and 0.30 +/- 0.22 ml/s, respectively. Diastolic peak and mean flows were 2.42 +/- 0.56 and 1.38 +/- 0.43 ml/s. The systolic to diastolic ratio was 0.37 +/- 0.12 for peak flow and 0.22 +/- 0.15 for mean flow. Mean flow through the cardiac cycle was 59.1 +/- 15.0 ml/min. In the RCA, systolic peak and mean flow values were 1.96 +/- 0.69 and 0.74 +/- 0.31 ml/s, respectively. Diastolic peak and mean flows were 1.80 +/- 0.53 and 0.83 +/- 0.20 ml/s, The systolic to diastolic ratio was 0.97 +/- 0.58 for peak flow and 0.85 +/- 0.39 for mean flow. Mean flow through the cardiac cycle was 38.4 +/- 10.8 ml/min. The in-plane velocity of the coronary artery cross-section was 6.4 +/- 1.8 cm/s for the LAD and 14.9 +/- 4.0 cm/s for the RCA (given by peak values in diasrole). Conclusion: It is confirmed noninvasively with MR that the LAD shows a predominantly diastolic flow, whereas the RCA shows about equal flow values in systole and diastole. Through-plane motion correction is required for assessing the true flow patterns. The in-plane velocities of the coronary artery cross-sections imply a maximum data acquisition time window, estimated at 58 ms for the LAD and at 23 ms for the RCA.
引用
收藏
页码:567 / 576
页数:10
相关论文
共 27 条
[1]   OBSERVATIONS ON ASSESSMENT OF CARDIAC HYPERTROPHY UTILIZING A CHAMBER PARTITION TECHNIQUE [J].
BOVE, KE ;
ROWLANDS, DT ;
SCOTT, RC .
CIRCULATION, 1966, 33 (04) :558-&
[2]   Coronary flow and coronary flow reserve measurements in humans with breath-held magnetic resonance phase contrast velocity mapping [J].
Davis, CP ;
Liu, PF ;
Hauser, M ;
Gohde, SC ;
vonSchulthess, GK ;
Debatin, JF .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :537-544
[3]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[4]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[5]   TRUE MYOCARDIAL MOTION TRACKING [J].
FISCHER, SE ;
MCKINNON, GC ;
SCHEIDEGGER, MB ;
PRINS, W ;
MEIER, D ;
BOESIGER, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :401-413
[6]   Effect of and correction for in-plane myocardial motion on estimates of coronary-volume flow rates [J].
Frayne, R ;
Polzin, JA ;
Mazaheri, Y ;
Grist, TM ;
Mistretta, CA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :815-828
[7]  
HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
[8]   Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification [J].
Hofman, MBM ;
Wickline, SA ;
Lorenz, CH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :568-576
[9]   Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: Effects of cardiac and respiratory motion [J].
Hofman, MBM ;
vanRossum, AC ;
Sprenger, M ;
Westerhof, N .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) :521-531
[10]   IN-VIVO VALIDATION OF MAGNETIC-RESONANCE BLOOD-VOLUME FLOW MEASUREMENTS WITH LIMITED SPATIAL-RESOLUTION IN SMALL VESSELS [J].
HOFMAN, MBM ;
VISSER, FC ;
VANROSSUM, AC ;
VINK, GQM ;
SPRENGER, M ;
WESTERHOF, N .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (06) :778-784