Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: Effects of cardiac and respiratory motion

被引:70
作者
Hofman, MBM
vanRossum, AC
Sprenger, M
Westerhof, N
机构
[1] FREE UNIV AMSTERDAM, DEPT CLIN PHYS, AMSTERDAM, NETHERLANDS
[2] FREE UNIV AMSTERDAM, DEPT ENGN, AMSTERDAM, NETHERLANDS
[3] FREE UNIV AMSTERDAM, DEPT PHYSIOL, AMSTERDAM, NETHERLANDS
[4] FREE UNIV AMSTERDAM, DEPT CARDIOL, AMSTERDAM, NETHERLANDS
[5] FREE UNIV AMSTERDAM, ICAR VU, AMSTERDAM, NETHERLANDS
关键词
flow quantification; coronary artery; MRI; volume flow;
D O I
10.1002/mrm.1910350411
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flow in the human right coronary artery was determined using magnetic resonance phase contrast velocity quantification. Two methods were applied to reduce respiratory motion: imaging during breath holding, which is fast, and retrospective respiratory gating, which has a high temporal resolution (32 ms) in the cardiac cycle. Vessel cross-sectional area, through-plane velocity, and volume flow were determined in six healthy subjects. In-plane vessel displacement during the cardiac cycle, caused by cardiac contraction, was about 2-4 mm within a time frame of 32 ms in systole and early diastole. The motion resulted in blurring of images obtained during breath holding caused by the large acquisition time window (126 ms) within the cardiac cycle. Therefore, only with a high temporal resolution correct velocity images over the entire cardiac cycle could be obtained. The time- and cross-sectionally averaged velocity was 7 +/- 2 cm/s, and the volume flow was 30 +/- 10 ml/min.
引用
收藏
页码:521 / 531
页数:11
相关论文
共 47 条
[1]   MR ANGIOGRAPHY OF PERIPHERAL, CAROTID, AND CORONARY-ARTERIES [J].
ALFIDI, RJ ;
MASARYK, TJ ;
HAACKE, EM ;
LENZ, GW ;
ROSS, JS ;
MODIC, MT ;
NELSON, AD ;
LIPUMA, JP ;
COHEN, AM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1097-1109
[2]   OBSERVATIONS ON ASSESSMENT OF CARDIAC HYPERTROPHY UTILIZING A CHAMBER PARTITION TECHNIQUE [J].
BOVE, KE ;
ROWLANDS, DT ;
SCOTT, RC .
CIRCULATION, 1966, 33 (04) :558-&
[3]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[4]  
BURNSTEIN D, 1990, P SMRM 9 ANN M, P80
[5]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[6]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378
[7]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[8]   CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS [J].
DOYLE, M ;
SCHEIDEGGER, MB ;
DEGRAAF, RG ;
VERMEULEN, J ;
POHOST, GM .
MAGNETIC RESONANCE IMAGING, 1993, 11 (01) :3-6
[9]   FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
GERVINO, E ;
LI, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :699-703
[10]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756