Cardiac multidetector-row CT:: Retrospectively ECG-gated spiral with optimized temporal and spatial resolution:: First clinical results.

被引:62
作者
Kopp, AF
Ohnesorge, B
Flohr, T
Georg, C
Schröder, S
Küttner, A
Martensen, J
Claussen, CD
机构
[1] Univ Tubingen, Radiol Klin, Abt Radiol Diagnost, D-72076 Tubingen, Germany
[2] Siemens AG, Med Tech, Forchheim, Germany
[3] Univ Tubingen, Med Klin, Abt Kardiol 3, D-7400 Tubingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 05期
关键词
multi-slice CT; spiral-CT; cardio CT; retrospective ECG-gating;
D O I
10.1055/s-2000-673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The significantly improved temporal and spatial resolution of Multidetector-Row CT opens up new possibilities for cardiac imaging. A method with retrospectively EGG-gated spiral acquisition is presented. Materials and Methods: A total of 10 patients underwent cardiac CT on a fast multi-slice CT system with 4 simultaneously acquired slices and 0.5 s rotation time (Siemens Somatom Volume Zoom). Continuous spiral data of the entire heart volume (5 studies precontrast for calcium scoring, 5 studies with contrast) were acquired together with the patient's ECG and reconstructed with dedicated spiral algorithms providing 250 ms temporal resolution. Three-dimensional image data sets were built up from overlapping slices that were reconstructed in an arbitrary, user-defined phase of the heart cycle (e.g., diastolic phase). To evaluate the capability of the method for functional imaging, complete image volumes were reconstructed from the same spiral data set in different phases of the heart cycle. Results: Within a single breath-hold, a spiral data set of the entire heart Volume could be acquired. Typical scan times for standard examinations with 3-mm slice width were 12-17 s, and for high-resolution CT angiographies of the coronary arteries with 1.25-mm slice width about 25-35 s. Motion-free reconstruction of the heart and coronary arteries with high spatial resolution were possible in the diastolic phase of the heart cycle. Multiphase reconstructions from the same spiral scan data set were possible. Conclusions: Fast multi-slice spiral CT with retrospectively EGG-gated spiral reconstruction is well suited for three-dimensional and functional imaging of the heart, especially for high-resolution imaging of calcified coronary plaques and CT-angiography of the coronary arteries.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 21 条
[1]
Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]
*AM HEART ASS COMM, 1999, CIRCULATION, V51, P7
[3]
Becker CR, 1999, RADIOLOGY, V213P, P351
[4]
New classes of helical weighting algorithms with applications to fast CT reconstruction [J].
Besson, G .
MEDICAL PHYSICS, 1998, 25 (08) :1521-1532
[5]
High temporal resolution volume heart imaging with multirow computed tomography [J].
Bruder, H ;
Schaller, S ;
Ohnesorge, B ;
Mertelmeier, T .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :420-432
[6]
Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study [J].
Budoff, MJ ;
Georgiou, D ;
Brody, A ;
Agatston, AS ;
Kennedy, J ;
Wolfkiel, C ;
Stanford, W ;
Shields, P ;
Lewis, RJ ;
Janowitz, WR ;
Rich, S ;
Brundage, BH .
CIRCULATION, 1996, 93 (05) :898-904
[7]
Flohr T, 1999, RADIOLOGY, V213P, P317
[8]
Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[9]
Subsecond multi-slice computed tomography: basics and applications [J].
Klingenbeck-Regn, K ;
Schaller, S ;
Flohr, T ;
Ohnesorge, B ;
Kopp, AF ;
Baum, U .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :110-124
[10]
Kopp AF, 1999, RADIOLOGY, V213P, P435