Multi-detector row CT systems and image-reconstruction techniques

被引:224
作者
Flohr, TG
Schaller, S
Stierstorfer, K
Bruder, H
Ohnesorge, BM
Schoepf, UJ
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[2] Siemens Med Solut, CT Div, Forchheim, Germany
[3] Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
关键词
D O I
10.1148/radiol.2353040037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction in 1998 of multi-detector row computed tomography (CT) by the major CT vendors was a milestone with regard to increased scan speed, improved z-axis spatial resolution, and better utilization of the available x-ray power. In this review, the general technical principles of multi-detector row CT are reviewed as they apply to the established four- and eight-settion systems, the most recent 16-section scanners, and future generations of multi-cletector row CT systems. Clinical examples are used to demonstrate both the potential and the limitations of the different scanner types. When necessary, standard single-section CT is referred. to as a common basis and starting point for further developments, Another focus is the increasingly important topic of patient radiation exposure, successful dose management, and strategies for dose reduction. Finally, the evolutionary steps from traditional single-section spiral image-reconstruction algorithms to the most recent approaches toward multisection spiral reconstruction are, traced.((c))RSNA, 2005.
引用
收藏
页码:756 / 773
页数:18
相关论文
共 98 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating
    Becker, CR
    Knez, A
    Ohnesorge, B
    Schoepf, UJ
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 423 - 424
  • [3] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [4] Bruder H, 2000, IEEE T MED IMAGING, V19, P873, DOI 10.1109/42.887836
  • [5] High temporal resolution volume heart imaging with multirow computed tomography
    Bruder, H
    Schaller, S
    Ohnesorge, B
    Mertelmeier, T
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 420 - 432
  • [6] CESMELI E, P SPIE MED IMAGING 2, V4320, P645
  • [7] COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION
    CRAWFORD, CR
    KING, KF
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 967 - 982
  • [8] Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital
    Donnelly, LF
    Emery, KH
    Brody, AS
    Laor, T
    Gylys-Morin, VM
    Anton, CG
    Thomas, SR
    Frush, DP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 303 - 306
  • [9] Ertl-Wagner B, 2002, RADIOLOGE, V42, P728, DOI 10.1007/s00117-002-0786-2
  • [10] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619