Computed tomography coronary angiography

被引:148
作者
Achenbach, Stephan [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
关键词
D O I
10.1016/j.jacc.2006.08.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent developments in computed tomography technology have made imaging of the coronary arteries possible. Ail the same, the rapid motion and small dimensions of the coronary vessels make coronary computed tomography angiography (coronary CTA) challenging. With the last generations of 16- and 64-slice computed tomography and adequate patient preparation (which includes lowering of the heart rate), rates of sensitivity ranging from 83% to 99% and specificity between 93% and 98% have been reported for the detection of coronary artery stenoses in comparison with invasive coronary angiography. The high negative predictive value (9S% to 100%) found in these studies suggests that coronary CTA may be a useful diagnostic technique to rule out the presence of coronary stenoses in selected patients, especially those with a rather low pretest likelihood of disease. Imaging of coronary artery bypass grafts is reliable, but clinical applications can be hampered by difficulties in assessing the native coronary arteries in patients after undergoing bypass because of their often-severe calcification. The detection of in-stent restenosis is made difficult by artifacts caused by metal, especially in smaller stents. Finally, initial reports that coronary CTA allows the detection and, to a certain extent, also the characterization and quantification of noncalcified coronary arteriosclerotic plaque are interesting, but they currently do not provide sufficient data to support clinical applications in the context of risk stratification.
引用
收藏
页码:1919 / 1928
页数:10
相关论文
共 76 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience
    Achenbach, S
    Ropers, D
    Kuettner, A
    Flohr, T
    Ohnesorge, B
    Bruder, H
    Theessen, H
    Karakaya, M
    Daniel, WG
    Bautz, W
    Kalender, WA
    Anders, K
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) : 331 - 335
  • [3] Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation
    Achenbach, S
    Ropers, D
    Pohle, FK
    Raaz, D
    von Erffa, J
    Yilmaz, A
    Muschiol, G
    Daniel, WG
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 (19) : 1978 - 1986
  • [4] Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography
    Achenbach, S
    Ropers, D
    Hofmann, U
    MacNeill, B
    Baum, U
    Pohle, K
    Brady, TJ
    Pomerantsev, E
    Ludwig, J
    Flachskampf, FA
    Wicky, S
    Jang, IK
    Daniel, WG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 842 - 847
  • [5] Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound
    Achenbach, S
    Moselewski, F
    Ropers, D
    Ferencik, M
    Hoffmann, U
    MacNeill, B
    Pohle, K
    Baum, U
    Anders, K
    Jang, I
    Daniel, WG
    Brady, TJ
    [J]. CIRCULATION, 2004, 109 (01) : 14 - 17
  • [6] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [7] Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography
    Anders, K
    Baum, U
    Schmid, M
    Ropers, D
    Schmid, A
    Pohle, K
    Daniel, WG
    Bautz, W
    Achenbach, S
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) : 336 - 344
  • [8] Aviram Galit, 2005, Int J Cardiovasc Intervent, V7, P21
  • [9] Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating
    Becker, CR
    Knez, A
    Ohnesorge, B
    Schoepf, UJ
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 423 - 424
  • [10] Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT
    Becker, CR
    Nikolaou, K
    Muders, M
    Babaryka, G
    Crispin, A
    Schoepf, UJ
    Loehrs, U
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (09) : 2094 - 2098