Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 30 条
[21]   Application- and patient size-dependent optimization of x-ray spectra for CT [J].
Kalender, Willi A. ;
Deak, Paul ;
Kellermeier, Markus ;
van Straten, Marcel ;
Vollmar, Sabrina V. .
MEDICAL PHYSICS, 2009, 36 (03) :993-1007
[22]   Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique [J].
Klass, Oliver ;
Jeltsch, Martin ;
Feuerlein, Sebastian ;
Brunner, Horst ;
Nagel, Hans-Dieter ;
Walker, Matthew J. ;
Brambs, Hans-Juergen ;
Hoffmann, Martin H. K. .
EUROPEAN RADIOLOGY, 2009, 19 (04) :829-836
[23]   Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography Comparison With Retrospective Electrocardiogram-Gated Helical Scan [J].
Maruyama, Takao ;
Takada, Masanori ;
Hasuike, Toshiaki ;
Yoshikawa, Atsushi ;
Namimatsu, Eiji ;
Yoshizumi, Tohru .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (18) :1450-1455
[24]   Strategies for reduction of radiation dose in cardiac multislice CT [J].
Paul, Jean-Francois ;
Abada, Hicham T. .
EUROPEAN RADIOLOGY, 2007, 17 (08) :2028-2037
[25]   Technical principles of dual source CT [J].
Petersilka, Martin ;
Bruder, Herbert ;
Krauss, Bernhard ;
Stierstorfer, Karl ;
Flohr, Thomas G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :362-368
[26]   Image Quality in a Low Radiation Exposure Protocol for Retrospectively ECG-Gated Coronary CT Angiography [J].
Pflederer, Tobias ;
Rudofsky, Larissa ;
Ropers, Dieter ;
Bachmann, Sven ;
Marwan, Mohamed ;
Daniel, Werner G. ;
Achenbach, Stephan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :1045-1050
[27]  
Raff Gilbert L, 2009, J Cardiovasc Comput Tomogr, V3, P122, DOI 10.1016/j.jcct.2009.01.001
[28]   Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance [J].
Scheffel, H. ;
Alkadhi, H. ;
Leschka, S. ;
Plass, A. ;
Desbiolles, L. ;
Guber, I. ;
Krauss, T. ;
Gruenenfelder, J. ;
Genoni, M. ;
Luescher, T. F. ;
Marincek, B. ;
Stolzmann, P. .
HEART, 2008, 94 (09) :1132-1137
[29]   Coronary CT angiography [J].
Schoepf, U. Joseph ;
Zwerner, Peter L. ;
Savino, Giancarlo ;
Herzog, Christopher ;
Kerl, J. Matthias ;
Costello, Philip .
RADIOLOGY, 2007, 244 (01) :48-63
[30]   Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: Comparison of image quality and patient radiation dose [J].
Shuman, William P. ;
Branch, Kelley R. ;
May, Janet M. ;
Mitsumori, Lee M. ;
Lockhart, David W. ;
Dubinsky, Theodore J. ;
Warren, Bill H. ;
Caldwell, James H. .
RADIOLOGY, 2008, 248 (02) :431-437