Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: Comparison of image quality and patient radiation dose

被引:303
作者
Shuman, William P. [1 ]
Branch, Kelley R. [2 ]
May, Janet M. [1 ]
Mitsumori, Lee M. [1 ]
Lockhart, David W. [3 ]
Dubinsky, Theodore J. [1 ]
Warren, Bill H. [1 ]
Caldwell, James H. [1 ,2 ]
机构
[1] Univ Washington, Sch Med, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Sch Med, Dept Med, Div Cardiol, Seattle, WA 98195 USA
[3] Univ Washington, Sch Med, Dept Biostat, Seattle, WA 98195 USA
关键词
D O I
10.1148/radiol.2482072192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare image quality and patient radiation dose in a group of patients who underwent 64-detector computed tomography (CT) coronary angiography performed with prospective electrocardiographic (ECG) gating with image quality and radiation dose in a group of patients matched for clinical features who underwent 64-detector CT coronary angiography performed with retrospective ECG gating. Materials and Methods: Institutional review board approval was obtained for this HIPAA-compliant study, and the informed consent requirement was waived due to the retrospective study design. Two independent reviewers separately scored coronary artery segment image quality and overall image quality for 100 cardiac CT studies (50 in each group). Interobserver variability was calculated. Patient radiation dose for the actual examination z-axis length was recorded, and a normalized dose was calculated for a 12-cm z-axis length of a typical heart. Results: The two groups matched well for clinical characteristics and CT parameters. There was good agreement for coronary artery segment image quality scores between the independent reviewers (kappa = 0.72). Of the 1253 coronary artery segments scored, the number of coronary artery segments that could not be evaluated in each group was similar (1.1% [ seven of 614] in the prospective group vs 1.5% [ 10 of 647] in the retrospective group, P = .53). Image quality scores were not significantly different when matched for chest cross-sectional area (P >.05). Mean patient radiation dose was 77% lower for prospective gating (4.2 mSv) than for retrospective gating (18.1 mSv) (P < .01). Conclusion: Use of 64-detector CT coronary angiography performed with prospective ECG gating has similar subjective image quality scores but 77% lower patient radiation dose when compared with use of retrospective ECG gating. (C) RSNA, 2008.
引用
收藏
页码:431 / 437
页数:7
相关论文
共 16 条
[1]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[2]  
Altman DG., 1990, PRACTICAL STAT MED R
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]  
Bongartz G, 2004, 16262 EUR EUR COMM
[5]   Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: Effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy [J].
Brodoefel, H. ;
Reimann, A. ;
Burgstahler, C. ;
Schumacher, F. ;
Herberts, T. ;
Tsiflikas, I. ;
Schroeder, S. ;
Claussen, C. D. ;
Kopp, A. F. ;
Heuschmid, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (01) :134-141
[6]  
Dowe D., 2006, DIAGN IMAGING S, V28, pS1
[7]   Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753
[8]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[9]   Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography - A meta-analysis [J].
Hamon, Michele ;
Biondi-Zoccai, Giuseppe G. L. ;
Malagutti, Patrizia ;
Agostoni, Pierfrancesco ;
Morello, Remy ;
Valgimigli, Marco ;
Hamon, Martial .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (09) :1896-1910
[10]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310