Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance

被引:216
作者
Scheffel, H. [1 ]
Alkadhi, H. [1 ]
Leschka, S. [1 ]
Plass, A. [2 ]
Desbiolles, L. [1 ]
Guber, I. [2 ]
Krauss, T. [1 ]
Gruenenfelder, J. [2 ]
Genoni, M. [2 ]
Luescher, T. F. [3 ]
Marincek, B. [1 ]
Stolzmann, P. [1 ]
机构
[1] Univ Zurich Hosp, Inst Diag Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
关键词
D O I
10.1136/hrt.2008.149971
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the performance of low-dose, dual-source computed tomography (DSCT) coronary angiography in the step-and-shoot (SAS) mode for the diagnosis of significant coronary artery stenoses in comparison with conventional coronary angiography (CCA). Design, setting and patients: Prospective, single-centre study conducted in a referral centre enrolling 120 patients (71 men, mean (SD) age 68 (9) years, mean (SD) body mass index 26.2 (3.2) kg/m(2)). All study participants underwent DSCT in the SAS mode and CCA within 14 days. Twenty-seven patients were given intravenous beta blockers for heart rate reduction before CT. Patients were excluded if a target heart rate <= 70 bpm could not be achieved by beta blockers or when the patients were in non-sinus rhythm. Two blinded readers independently evaluated coronary artery segments for assessability and for the presence of significant (>50%) stenoses. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) were determined, with CCA being the standard of reference. Radiation dose values were calculated. Results: DSCT coronary angiography in the SAS mode was successfully performed in all 120 patients. Mean (SD) heart rate during scanning was 59 (6) bpm (range 44-69). 1773/1803 coronary segments (98%) were depicted with a diagnostic image quality in 109/120 patients (91%). The overall patient-based sensitivity, specificity, PPV and NPV for the diagnosis of significant stenoses were 100%, 93%, 94% and 100%, respectively. The mean (SD) effective dose of the CT protocol was 2.5 (0.8) mSv (range 1.2-4.4). Conclusions: DSCT coronary angiography in the SAS mode allows, in selected patients with a regular heart rate, the accurate diagnosis of significant coronary stenoses at a low radiation dose.
引用
收藏
页码:1132 / 1137
页数:6
相关论文
共 30 条
[1]   MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose [J].
Abada, Hicham T. ;
Larchez, Christophe ;
Daoud, Beatrice ;
Sigal-Cinqualbre, Anne ;
Paul, Jean-Francois .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S387-S390
[2]  
Alkadhi Hatem, 2008, J Cardiovasc Comput Tomogr, V2, P91, DOI 10.1016/j.jcct.2008.02.003
[3]   Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy [J].
Alkadhi, Hatem ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Gaemperli, Oliver ;
Stolzmann, Paul ;
Plass, Andre ;
Goerres, Gerhard W. ;
Luescher, Thomas F. ;
Genoni, Michele ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Leschka, Sebastian .
EUROPEAN HEART JOURNAL, 2008, 29 (06) :766-776
[4]  
Austen W G, 1975, Circulation, V51, P5
[5]   Which patients should be referred for non-invasive angiography with multi-slice CT? [J].
Bax, Jeroen J. ;
Schuijf, Joanne D. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 114 (01) :1-3
[6]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[7]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[8]   Use of automatic exposure control in multislice computed tomography of the coronaries:: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography [J].
Deetjen, Anja ;
Moellmann, Susanne ;
Conradi, Guido ;
Rolf, Andreas ;
Schmermund, Axel ;
Hamm, Christian W. ;
Dill, Thorsten .
HEART, 2007, 93 (09) :1040-1043
[9]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[10]   Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753