Strategies for CT radiation dose optimization

被引:775
作者
Kalra, MK
Maher, MM
Toth, TL
Hamberg, LM
Blake, MA
Shephard, JA
Saini, S
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Gen Elect Med Syst, Milwaukee, WI USA
关键词
computed tomography (CT); image quality; multidetector row; radiation exposure; radiations; exposure to patients and personnel; review;
D O I
10.1148/radiol.2303021726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent technologic advances have markedly enhanced the clinical applications of computed tomography (CT). While the benefits of CT exceed the harmful effects of radiation exposure in patients, increasing radiation doses to the population have raised a compelling case for reduction of radiation exposure from CT. Strategies for radiation dose reduction are difficult to devise, however, because of a lack of guidelines regarding CT examination and scanning techniques. Various methods and strategies based on individual patient attributes and CT technology have been explored for dose optimization. It is the purpose of this review article to outline basic principles of CT radiation exposure and emphasize the need for CT radiation dose optimization based on modification of scanning parameters and application of recent technologic innovations. (C) RSNA, 2004.
引用
收藏
页码:619 / 628
页数:10
相关论文
共 78 条
  • [1] OPTIMAL PROCESSING OF COMPUTED TOMOGRAPHY IMAGES USING EXPERIMENTALLY MEASURED NOISE PROPERTIES
    ALVAREZ, RE
    STONESTROM, JP
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) : 77 - 84
  • [2] [Anonymous], 2000 REP GEN ASS ANN
  • [3] Would thyroid and breast shielding be beneficial in CT of the head?
    Beaconsfield, T
    Nicholson, R
    Thornton, A
    Al-Kutoubi, A
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (04) : 664 - 667
  • [4] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [5] Population exposure to diagnostic use of ionizing radiation in the Netherlands
    Brugmans, MJP
    Buijs, WCAM
    Geleijns, J
    Lembrechts, J
    [J]. HEALTH PHYSICS, 2002, 82 (04): : 500 - 509
  • [6] USAGE OF DIAGNOSTIC-IMAGING PROCEDURES - A NATIONWIDE HOSPITAL STUDY
    BUNGE, RE
    HERMAN, CL
    [J]. RADIOLOGY, 1987, 163 (02) : 569 - 573
  • [7] Cohnen M, 2000, AM J NEURORADIOL, V21, P1654
  • [8] Multi-slice CT-colonography in low-dose technique -: Preliminary results
    Cohnen, M
    Vogt, C
    Aurich, V
    Beck, A
    Häussinger, D
    Mödder, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07): : 835 - 838
  • [9] A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved
    Crawley, MT
    Booth, A
    Wainwright, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883) : 607 - 614
  • [10] Pulmonary nodules: Experimental and clinical studies at low-dose CT
    Diederich, S
    Lenzen, H
    Windmann, R
    Puskas, Z
    Yelbuz, TM
    Henneken, S
    Klaiber, T
    Eameri, M
    Roos, N
    Peters, PE
    [J]. RADIOLOGY, 1999, 213 (01) : 289 - 298