Cervical spine biomechanics following implantation of a disc prosthesis

被引:92
作者
Galbusera, Fabio [1 ]
Bellini, Chiara M. [1 ]
Raimondi, Manuela T. [1 ,2 ]
Fornari, Maurizio [1 ]
Assietti, Roberto [3 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
[2] Politecn Milan, Dept Struct Engn, LaBS, I-20133 Milan, Italy
[3] Osped Fatebenefratelli & Oftalm, Milan, Italy
关键词
Finite element; Cervical arthroplasty; Artificial disc; Cervical disc prosthesis;
D O I
10.1016/j.medengphy.2008.02.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
This study presents a finite element model of the C4-C7 segment in healthy conditions and after implantation of a disc prosthesis at a single level, in order to investigate of the influence of disc arthroplasty on the biomechanics of the cervical spine. A nonlinear finite element model of the C4-C7 segment in intact conditions was developed and run in flexion and extension. A detailed model of the Bryan disc prosthesis, including contacts between the different components of the device, was built and positioned at C5-C6. The calculated segmental motion resulted preserved after disc arthroplasty, with respect to the model of the intact spine, in both flexion and extension. A general preservation of the forces transmitted through the facet joints was obtained; a minor force increase at the implanted level was detected. The analysis of the instantaneous centers of rotation (ICR) in flexion-extension showed the preservation of a physiological kinematics. The mechanical behaviour showed an asymmetry between flexion and extension, probably due to the removal of the anterior longitudinal ligament and the anterior part of the annulus fibrosus, and the preservation of the posterior structures. In general, the disc prosthesis showed to be able to reproduce a nearly physiological motion. However, other important mechanical aspects, such as the possible micromotion at the bone-implant interface and the possible degenerative conditions of the spine, need to be evaluated before drawing a conclusion about total disc arthroplasty from an engineering point of view. (C) 2008 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1127 / 1133
页数:7
相关论文
共 31 条
[1]
[Anonymous], 2002, GNU Octave Manual
[2]
Range of motion change after cervical arthroplasty with ProDisc-C and Prestige artificial discs compared with anterior cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :40-46
[3]
Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :33-39
[4]
Prospective randomized controlled study of the Bryan Cervical Disc: early clinical results from a single investigational site - Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005 [J].
Coric, D ;
Finger, F ;
Boltes, P .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (01) :31-35
[5]
An accurate finite element model of the cervical spine under quasi-static loading [J].
del Palomar, A. Perez ;
Calvo, B. ;
Doblare, M. .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :523-531
[6]
Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc [J].
Denozière, G ;
Ku, DN .
JOURNAL OF BIOMECHANICS, 2006, 39 (04) :766-775
[7]
DiAngelo Denis J, 2004, Neurosurg Focus, V17, pE7
[8]
DiAngelo Denis J, 2004, Neurosurg Focus, V17, pE4
[9]
Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty -: An In Vitro human cadaveric model [J].
Dmitriev, AE ;
Cunningham, BW ;
Hu, NB ;
Sell, G ;
Vigna, F ;
McAfee, PC .
SPINE, 2005, 30 (10) :1165-1172
[10]
Load-Sharing Between Anterior and Posterior Elements in a Lumbar Motion Segment Implanted With an Artificial Disc [J].
Dooris, Andrew P. ;
Goel, Vijay K. ;
Grosland, Nicole M. ;
Gilbertson, Lars G. ;
Wilder, David G. .
SPINE, 2001, 26 (06) :E122-E129