High-throughput quantification of drugs and their metabolites in biosamples by LC-MS/MS and CE-MS/MS: Possibilities and limitations

被引:27
作者
Hopfgartner, G [1 ]
Husser, C [1 ]
Zell, M [1 ]
机构
[1] F Hoffmann La Roche & Co Ltd, Div Pharmaceut, Nonclin Dev Drug Safety, CH-4070 Basel, Switzerland
关键词
fast analysis; mass spectrometry; atmospheric pressure ionization; ion spray; high performance liquid chromatography; turbulent flow chromatography; capillary electrophoresis;
D O I
10.1097/00007691-200202000-00021
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Off-line solid phase extraction with C18 disk plates and turbulent flow chromatography were evaluated versus on-line solid phase extraction using column-switching HPLC as sample preparation techniques for high-throughput analysis of pharmaceutical compounds and their metabolites by LC-MS/MS. Turbulent flow chromatography was found to be very straightforward in its applicaton, but the LOQs were more than fivefold higher compared with off-line or other on-line solid phase extraction methods. Solid phase extraction (SPE) on disk was found to be fast and sufficient efficient to minimize matrix effects and therefore an apprach to provide sensitive and reliable LC-MS/MS methods. Column-switching HPLC with microbore columns (0.5 mm i.d.) were used for fast analysis of a parent drug and four of its metabolites utilizing steep gradients in 1 minute. The application of CZE-MS/MS for bionalysis of pharamaceutical compounds is also discussed.
引用
收藏
页码:134 / 143
页数:10
相关论文
共 27 条
[1]  
Ayrton J, 1999, RAPID COMMUN MASS SP, V13, P1657, DOI 10.1002/(SICI)1097-0231(19990830)13:16<1657::AID-RCM694>3.0.CO
[2]  
2-L
[3]  
Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
[4]  
2-2
[5]  
Biddlecombe RA, 2001, RAPID COMMUN MASS SP, V15, P33, DOI 10.1002/1097-0231(20010115)15:1<33::AID-RCM188>3.0.CO
[6]  
2-4
[7]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[8]  
2-S
[9]   Multiple-sprayer tandem mass spectrometry with parallel high flow extraction and parallel separation for high-throughput quantitation in biological fluids [J].
Deng, YZ ;
Zeng, H ;
Unger, SE ;
Wu, JT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (17) :1634-1640
[10]   Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine [J].
Deng, YZ ;
Henion, J ;
Li, JJ ;
Thibault, P ;
Wang, C ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :639-646