MRI detection of radiographically occult fractures of the hip and pelvis in the elderly: Comparison of T2-weighted Dixon sequence with T1-weighted and STIR sequences

被引:23
作者
Heynen, B. [1 ]
Tamigneaux, C. [1 ]
Pasoglou, V. [1 ]
Malghem, J. [1 ]
Vande Berg, B. [1 ]
Kirchgesner, T. [1 ]
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, Dept Med Imaging, IREC, B-1200 Brussels, Belgium
关键词
Bone fracture; Hip; Pelvis; MRI; Dixon sequence; FAT-SUPPRESSION; EMERGENCY-DEPARTMENT; DIAGNOSIS; CT; PREVALENCE;
D O I
10.1016/j.diii.2018.11.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To compare the diagnostic performance of T2-weighted Dixon, T1-weighted and Short- Tau Inversion Recovery (STIR) MR images for the detection of radiographically occult fractures (RDF) of the hip and pelvis in elderly patients after low-energy trauma. Materials and methods: A total of 22 patients older than 50 years with suspected ROF after low-energy trauma was prospectively included. There were 9 men and 13 women, with a mean age of 80.9 years +/- 12.5 (SD) (range: 52-100 years). T2-weighted Dixon, T1-weighted and STIR MR images were analyzed by 3 independent radiologists blinded to the clinical data and the results of other imaging examinations. Readers separately assessed each series of images for the presence of fractures on a per bone analysis. Diagnostic performance of each reader was compared for Dixon and non-Dixon sequences using contingency tables and McNemar test. Interobserver agreement was evaluated according to the Fleiss-Cuzick's kappa statistics. Results: The sensitivity of the Dixon sequence in the detection of ROF ranged from 90.9% (20/22; 95% CI: 70.8-98.9%) to 100% (22/22; 95% CI: 84.6-100%). The sensitivities of the non-Dixon sequences in the detection of ROF ranged from 95.5% (21/22; 95% CI: 77.2-99.9%) to 100% (22/22; 95% CI: 84.6-100%). For each reader, there were no statistical differences between combined Dixon and combined non-Dixon images for the detection of ROF (P = 0.12, 0.99 and 0.99). Interobserver agreement with T2-weighted Dixon water-only images was significantly lower than that with the STIR sequence (0.70-0.79 vs. 0.87-0.93). Conclusion: T2-weighted Dixon may be a second-rate alternative to T1-weighted and STIR sequences for the detection of ROF of the hip and pelvis in elderly patients. (C) 2018 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 27 条
[1]
How to Demonstrate Similarity by Using Noninferiority and Equivalence Statistical Testing in Radiology Research [J].
Ahn, Soyeon ;
Park, Seong Ho ;
Lee, Kyoung Ho .
RADIOLOGY, 2013, 267 (02) :328-338
[2]
Berger P E, 1989, Radiographics, V9, P407
[3]
Comparing T1-weighted and T2-weighted three-point Dixon technique with conventional T1-weighted fat-saturation and short-tau inversion recovery (STIR) techniques for the study of the lumbar spine in a short-bore MRI machine [J].
Brandao, S. ;
Seixas, D. ;
Ayres-Basto, M. ;
Castro, S. ;
Neto, J. ;
Martins, C. ;
Ferreira, J. C. ;
Parada, F. .
CLINICAL RADIOLOGY, 2013, 68 (11) :E617-E623
[4]
MRI and CT of Insufficiency Fractures of the Pelvis and the Proximal Femur [J].
Cabarrus, Miguel C. ;
Ambekar, Avanti ;
Lu, Ying ;
Link, Thomas M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) :995-1001
[5]
Chiang IC, 2018, CLIN RADIOL, DOI [10.1016/j.crad.09.007, DOI 10.1016/J.CRAD.09.007]
[6]
Computed tomography compared to magnetic resonance imaging in occult or suspect hip fractures. A retrospective study in 44 patients [J].
Collin, David ;
Geijer, Mats ;
Gothlin, Jan H. .
EUROPEAN RADIOLOGY, 2016, 26 (11) :3932-3938
[7]
Prevalence of exclusively and concomitant pelvic fractures at magnetic resonance imaging of suspect and occult hip fractures [J].
Collin D. ;
Geijer M. ;
Göthlin J.H. .
Emergency Radiology, 2016, 23 (1) :17-21
[8]
HIP-FRACTURES IN THE ELDERLY - A WORLDWIDE PROJECTION [J].
COOPER, C ;
CAMPION, G ;
MELTON, LJ .
OSTEOPOROSIS INTERNATIONAL, 1992, 2 (06) :285-289
[9]
Pelvic ramus fractures in the elderly - 50 patients studied with MRI [J].
Cosker, TDA ;
Ghandour, A ;
Gupta, SK ;
Tayton, KJJ .
ACTA ORTHOPAEDICA, 2005, 76 (04) :513-516
[10]
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System [J].
Del Grande, Filippo ;
Santini, Francesco ;
Herzka, Daniel A. ;
Aro, Michael R. ;
Dean, Cooper W. ;
Gold, Garry E. ;
Carrino, John A. .
RADIOGRAPHICS, 2014, 34 (01) :217-233