Cathodic stripping potentiometric determination of selenium in biological and environmental materials on a combined electrode with a rotating sample platform

被引:21
作者
Adeloju, SB
Jagner, D
Renman, L
机构
[1] GOTHENBURG UNIV,DEPT ANALYT & MARINE CHEM,S-41296 GOTHENBURG,SWEDEN
[2] CHALMERS UNIV TECHNOL,S-41296 GOTHENBURG,SWEDEN
关键词
cathodic stripping potentiometry; selenium; biological and environmental materials; combined working-counter-reference electrode; dry ashing; water;
D O I
10.1016/S0003-2670(96)00433-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of a combined working(glassy carbon mercury film electrode)-counter-reference electrode and a rotating sample platform for the reliable determination of selenium in biological and environmental materials by cathodic stripping potentiometry is described. The optimum conditions for the determination of selenium by this method include an electrolyte consisting of 2 M HCl and 1 M CaCl2, an electrolysis potential of -200 mV and a stripping current of -5 mu A. Under these conditions, as little as 0.1 mu g/l of selenium can be detected with an electrolysis time of 120 s, and the precision at this level was within 1-3% rsd. The interferences of organic and inorganic substances on the cathodic stripping potentiometric determination of selenium were minimal, except for copper which gave an additional peak when present at >2 mg/l. Even in this case, the copper interference can be overcome or reduced by sample dilution. The use of a dry ashing method with the technique enabled the reliable determination of selenium in biological and environmental materials. The direct determination of selenium in water samples by cathodic stripping potentiometry on the combined electrode is demonstrated.
引用
收藏
页码:199 / 207
页数:9
相关论文
共 17 条
[1]   DETERMINATION OF SELENIUM, COPPER, LEAD AND CADMIUM IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE STRIPPING VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
HUGHES, HC .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :59-69
[2]   STRIPPING VOLTAMMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS BY DIRECT CALIBRATION [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH ;
HUGHES, HC .
ANALYTICAL CHEMISTRY, 1983, 55 (13) :2076-2082
[3]  
Adeloju SB, 1996, ANAL LETT, V29, P283
[4]   CATHODIC STRIPPING POTENTIOMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL AND ENVIRONMENTAL MATERIALS [J].
ADELOJU, SB ;
YOUNG, TM .
ANALYTICA CHIMICA ACTA, 1994, 296 (01) :69-76
[5]   VOLTAMMETRIC DEPOSITION AND STRIPPING OF SELENIUM(IV) AT A ROTATING GOLD-DISK ELECTRODE IN 0.1M PERCHLORIC-ACID [J].
ANDREWS, RW ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :294-299
[7]  
CHRISTIA.GD, 1965, J ASSOC OFF AGR CHEM, V48, P877
[8]   AUTOMATED-DETERMINATION OF TOTAL ARSENIC IN SEA-WATER BY FLOW CONSTANT-CURRENT STRIPPING ANALYSIS WITH GOLD FIBER ELECTRODES [J].
HUA, C ;
JAGNER, D ;
RENMAN, L .
ANALYTICA CHIMICA ACTA, 1987, 201 :263-268
[9]   DETERMINATION OF SELENIUM BY MEANS OF COMPUTERIZED FLOW CONSTANT-CURRENT STRIPPING AT CARBON-FIBER ELECTRODES - APPLICATION TO HUMAN WHOLE-BLOOD AND MILK POWDER [J].
HUA, C ;
JAGNER, D ;
RENMAN, L .
ANALYTICA CHIMICA ACTA, 1987, 197 :257-264
[10]   RAPID METHOD FOR THE DETERMINATION OF COPPER(II) AND LEAD(II) IN TAP WATER USING A PORTABLE POTENTIOMETRIC STRIPPING ANALYZER [J].
JAGNER, D ;
SAHLIN, E ;
AXELSSON, B ;
RATANAOHPAS, R .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :237-242