RAPID METHOD FOR THE DETERMINATION OF COPPER(II) AND LEAD(II) IN TAP WATER USING A PORTABLE POTENTIOMETRIC STRIPPING ANALYZER

被引:34
作者
JAGNER, D
SAHLIN, E
AXELSSON, B
RATANAOHPAS, R
机构
[1] CHALMERS UNIV TECHNOL,S-41296 GOTHENBURG,SWEDEN
[2] PRINCE SONGKLA UNIV,DEPT CHEM,SONGKHLA 90112,THAILAND
关键词
POTENTIOMETRY; STRIPPING VOLTAMMETRY; COPPER; LEAD; WATER;
D O I
10.1016/0003-2670(93)85105-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tap water samples of 400 mul were added to 200 mul of matrix-modifying solution consisting of hydrochloric acid, calcium chloride, mercury(II), ethanol, Triton X-100 and bismuth(III) as internal standard and contained in disposable 2-ml Eppendorff sample tubes. The mixture was analysed for copper(II) and lead(II) using a commercial computerized potentiometric stripping analyser in combination with a laboratory-made electrode system and rotating sample holder. Copper(II) in the range 0.10-5 mg l-1 was determined in less than 1 min and lead(II) in the range 1-50 mug l-1 in 3 min, the precisions being ca. 15%.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 11 条
[1]   EVALUATION OF ANTIMONY, CADMIUM AND LEAD LEVELS IN VEGETABLES, DRINKING AND RAW WATER FROM DIFFERENT AGRICULTURAL AREAS [J].
ALEGRIA, A ;
BARBERA, R ;
FARRE, R ;
LAGARDA, MJ ;
ROIG, MJ ;
ROMERO, I .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) :65-73
[2]   IMPROVEMENT OF THE DETECTION POWER IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY BY SUMMATION OF SIGNALS - DETERMINATION OF TRACES OF METALS IN DRINKING-WATER AND URINE [J].
BERNDT, H ;
SCHALDACH, G ;
KLOCKENKAMPER, R .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :573-579
[3]   USE OF MASKING AGENTS IN THE DETERMINATION OF LEAD IN TAP WATER BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION PRECONCENTRATION [J].
BYSOUTH, SR ;
TYSON, JF ;
STOCKWELL, PB .
ANALYST, 1990, 115 (05) :571-573
[4]  
DAVIS WF, 1990, AM IND HYG ASSOC J, V51, P620, DOI 10.1080/15298669091370257
[5]   MICROCOMPUTER SYSTEM FOR POTENTIOMETRIC STRIPPING ANALYSIS [J].
GRANELI, A ;
JAGNER, D ;
JOSEFSON, M .
ANALYTICAL CHEMISTRY, 1980, 52 (13) :2220-2223
[6]   A NOVEL BATCH ELECTRODE DESIGN FOR USE IN STRIPPING POTENTIOMETRY FACILITATING MEDIUM EXCHANGE [J].
JAGNER, D ;
RENMAN, L ;
WANG, YD .
ELECTROANALYSIS, 1992, 4 (03) :267-273
[7]  
JAGNER D, 1992, ELECTROANALYSIS, V5
[8]   COMPARISONS OF 3 DIFFERENT ENRICHMENT TECHNIQUES IN THE DETERMINATION OF LEAD IN TAP WATER AND BOTTLED WATER BY FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
KOKLU, U ;
AKMAN, S .
ANALYTICAL LETTERS, 1990, 23 (03) :569-576
[9]  
LYNGBYE T, 1987, THESIS ODENSE U
[10]   COMPUTER-SYSTEM AND FLOW CELL FOR AUTOMATED POTENTIOMETRIC AND CONSTANT-CURRENT STRIPPING ANALYSIS [J].
RENMAN, L ;
JAGNER, D ;
BERGLUND, R .
ANALYTICA CHIMICA ACTA, 1986, 188 :137-150