Performance and Abnormal Cell Flagging Comparisons of Three Automated Blood Cell Counters

被引:51
作者
Hotton, Julie
Broothaers, Jan
Swaelens, Caroline
Cantinieaux, Brigitte
机构
[1] Univ Libre Bruxelles, CHU St Pierre, Haematol Lab, Brussels, Belgium
[2] Univ Libre Bruxelles, Bordet Inst, Brussels, Belgium
关键词
Cell-Dyn Sapphire; DxH-800; XN-2000; HemaCAM; Flag; Blast; Abnormal lymphocytes; IG; NRBC; SYSMEX; XE-2100;
D O I
10.1309/AJCPE5R4SOQBUULZ
中图分类号
R36 [病理学];
学科分类号
100103 [病原生物学];
摘要
Objectives: To compare two hematological analyzers-the DxH-800 (DxH; Beckman-Coulter, Miami, FL) and XN-2000 (XN; Sysmex, Kobe, Japan)-with the Cell-Dyn Sapphire (SAPH; Abbott, Santa Clara, CA). Methods: We analyzed 4,375 samples. Slide reviews were made in the presence of blast, abnormal lymphocyte, and immature granulocyte (IG) flags or nucleated RBC (NRBC) count. Results: The analyzers exhibited excellent correlations for CBC and neutrophils but displayed a limit correlation for lymphocytes. The XN did not miss circulating blasts (0.5%-95% in microscopy). For NRBCs, the XN demonstrated a sensitivity of 90%; DxH, 74%; and SAPH, 29%. Only the XN demonstrated a correlation with microscopy, permitting a WBC six-part differential until 15% of NRBCs. The XN and DxH gave useful IG counts with a cutoff less than 5% and a WBC level more than 2,500/mm(3). For abnormal lymphocytes detection, only XN demonstrated sensitivity of more than 95%, but its specificity of 54% requires adaptation. Conclusion: The XN increases the sensitivity of abnormal cell detection compared with the other counters, permitting a seven-part differential between predefined levels, decreasing the slide review from 20% to 9%. (C) American Society for Clinical Pathology
引用
收藏
页码:845 / 852
页数:8
相关论文
共 13 条
[1]
[Anonymous], 2001, GOOD PRACT GUID REP
[2]
Briggs Carol, 2003, Lab Hematol, V9, P117
[3]
Improved Flagging Rates on the Sysmex XE-5000 Compared With the XE-2100 Reduce the Number of Manual Film Reviews and Increase Laboratory Productivity [J].
Briggs, Carol J. ;
Linssen, Joachim ;
Longair, Ian ;
Machin, Samuel J. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2011, 136 (02) :309-316
[4]
Clinical and Laboratory Standards Institute (CLSI), 2007, CLSI Document H20-A2, V2nd
[5]
CLSI, 2010, CLSI document H26-A2, V2nd
[6]
Cornbleet P J., 1995, Lab Hematol, V1, P89
[7]
The utility of the Sysmex XE-2100 analyzer's NEUT-X and NEUT-Y parameters for detecting neutrophil dysplasia in myelodysplastic syndromes [J].
Furundarena, J. R. ;
Araiz, M. ;
Uranga, M. ;
Sainz, M. R. ;
Agirre, A. ;
Trassorras, M. ;
Uresandi, N. ;
Montes, M. C. ;
Argoitia, N. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2010, 32 (03) :360-366
[8]
Henry J.B., 2001, CLIN DIAGNOSIS MANAG, V20th
[9]
Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness [J].
Kang, S. -H. ;
Kim, H. K. ;
Ham, C. K. ;
Lee, D. S. ;
Cho, H. -I. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2008, 30 (06) :480-486
[10]
Performance evaluation of the CellaVision DM96 system WBC differentials by automated digital image analysis supported by an artificial neural network [J].
Kratz, A ;
Bengtsson, HI ;
Casey, JE ;
Keefe, JM ;
Beatrice, GH ;
Grzybek, DY ;
Lewandrowski, KB ;
Van Cott, EM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (05) :770-781