High-resolution FMRI at 1.5T using balanced SSFP

被引:59
作者
Miller, KL
Smith, SM
Jezzard, P
Pauly, JM
机构
[1] Univ Oxford, Oxford Ctr Funct MRI Brain, FMRIB, Oxford, England
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
FIVIRI; BOLD; high resolution; SSFP; 3D imaging;
D O I
10.1002/mrm.20753
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The resolution in conventional BOLD FMRI is considerably lower than can be achieved with other MRI methods, and is insufficient for many important applications. One major difficulty in robustly improving spatial resolution is the poor image quality in BOLD FMRI, which suffers from distortions, blurring, and signal dropout. This work considers the potential for increased resolution with a new FMRI method based on balanced SSFP. This method establishes a blood oxygenation sensitive steady-state (BOSS) signal, in which the frequency sensitivity of balanced SSFP is used to detect the frequency shift of deoxyhemoglobin. BOSS FMRI is highly SNR efficient and does not suffer from image distortions or signal dropout, making this method an excellent candidate for high-resolution FMRI. This study presents the first demonstration of high-resolution BOSS FMRI, using an efficient 3D stack-of-segmented EPI readout and combined acquisition at multiple center frequencies. BOSS FMRI is shown to enable high-resolution FMRI data (1 x 1 x 2 mm(3)) in both visual and motor systems using standard hardware at 1.5 T. Currently, the major limitation of BOSS FMRI is its sensitivity to temporal and spatial field drift.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 44 条
[1]   High-resolution, multiple gradient-echo functional MRI at 1.5 T [J].
Barth, M ;
Reichenbach, JR ;
Venkatesan, R ;
Moser, E ;
Haacke, EM .
MAGNETIC RESONANCE IMAGING, 1999, 17 (03) :321-329
[2]  
BECKMAN CB, P 9 OHBM NEW YORK 20, P976
[3]   INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
THOMPSON, RM ;
JACK, CR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :67-72
[4]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[5]   Predicting BOLD signal changes as a function of blood volume fraction and resolution [J].
Cheng, YCN ;
Haacke, EM .
NMR IN BIOMEDICINE, 2001, 14 (7-8) :468-477
[6]  
CLARE S, 1996, P ISMRM 4 ANN M, P1821
[7]   High-resolution, spin-echo BOLD, and CBF AM at 4 and 7 T [J].
Duong, TQ ;
Yacoub, E ;
Adriany, G ;
Hu, XP ;
Ugurbil, K ;
Vaughan, JT ;
Merkle, H ;
Kim, SG .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :589-593
[8]   Retinotopic organization in human visual cortex and the spatial precision of functional MRI [J].
Engel, SA ;
Glover, GH ;
Wandell, BA .
CEREBRAL CORTEX, 1997, 7 (02) :181-192
[9]  
Everitt BS, 1999, HUM BRAIN MAPP, V7, P1
[10]   Frequency-modulated steady-state free precession imaging [J].
Foxall, DL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :502-508