Regularized autoregressive analysis of intravascular ultrasound backscatter: Improvement in spatial accuracy of tissue maps

被引:43
作者
Nair, A
Calvetti, D
Vince, DG
机构
[1] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
关键词
D O I
10.1109/TUFFC.2004.1295427
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Autoregressive (AR) models are qualified for analysis of stochastic, short-time data, such as intravascular ultrasound (IVUS) backscatter. Regularization is required for AR analysis of short data lengths with an aim to increase spatial accuracy of predicted plaque composition and was achieved by determining suitable AR orders for short data records. Conventional methods of determining order were compared to the use of trend in the mean square error for determining order. Radio-frequency data from 101 fibrous, 56 fibro-lipidic, 50 calcified, and 70 lipid-core regions of interest (ROIs) were collected ex vivo from 51 human coronary arteries with 30 MHz unfocused IVUS transducers. Spectra were computed for AR model orders between 3-20 for data representing ROIs of two sizes (32 and 16 samples at 100 MHz sampling frequency) and were analyzed in the 17-42 MHz bandwidth. These spectra were characterized based on eight previously identified parameters. Statistical classification schemes were computed from 75% of the data and cross-validated with the remaining 25% using matched histology. The results determined the suitable AR order numbers for the two ROI sizes. Conventional methods of determining order did not perform well. Trend in the mean square error was identified as the most suitable factor for regularization of short record lengths.
引用
收藏
页码:420 / 431
页数:12
相关论文
共 33 条
[1]  
*AM HEART ASS, 2003, HEART DIS STROK STAT
[2]   Continuation methods for the computation of zeros of Szego polynomials [J].
Ammar, GS ;
Calvetti, D ;
Reichel, L .
LINEAR ALGEBRA AND ITS APPLICATIONS, 1996, 249 :125-155
[3]   APPLICATION OF AUTOREGRESSIVE SPECTRAL-ANALYSIS FOR ULTRASOUND ATTENUATION ESTIMATION - INTEREST IN HIGHLY ATTENUATING MEDIUM [J].
BALDEWECK, T ;
LAUGIER, P ;
HERMENT, A ;
BERGER, G .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (01) :99-110
[4]   Parametric (integrated backscatter and attenuation) images constructed using backscattered radio frequency signals (25-56 MHz) from human aortae in vitro [J].
Bridal, SL ;
Fornes, P ;
Bruneval, P ;
Berger, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :215-229
[5]  
Burg J.P., 1978, MODERN SPECTRUM ANAL, P34
[6]  
BURG JP, 1978, MODERN SPECTRUM ANAL, P42
[7]   Autoregressive spectral estimation in ultrasonic scatterer size imaging [J].
Chaturvedi, P ;
Insana, MF .
ULTRASONIC IMAGING, 1996, 18 (01) :10-24
[8]  
Foster F S, 1997, Semin Interv Cardiol, V2, P33
[9]   Time-varying autoregressive spectral estimation for ultrasound attenuation in tissue characterization [J].
Girault, JM ;
Ossant, F ;
Ouahabi, A ;
Kouame, D ;
Patat, F .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :650-659
[10]   Processing radio frequency ultrasound images: A robust method for local spectral features estimation by a spatially constrained parametric approach [J].
Gorce, JM ;
Friboulet, D ;
Dydenko, I ;
D'hooge, J ;
Bijnens, BH ;
Magnin, IE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (12) :1704-1719