Hypersensitivity cases associated with drug-eluting coronary stents - A review of available cases from the research on adverse drug events and reports (RADAR) project

被引:485
作者
Nebeker, JR [1 ]
Virmani, R
Bennett, CL
Hoffman, JM
Samore, MH
Alvarez, J
Davidson, CJ
McKoy, JM
Raisch, DW
Whisenant, BK
Yarnold, PR
Belknap, SM
West, DP
Gage, JE
Morse, RE
Gligoric, G
Davidson, L
Feldman, MD
机构
[1] Vet Adm Salt Lake City, GRECC 182, Salt Lake City, UT 84148 USA
[2] Vet Adm Chicago, Chicago, IL USA
[3] Vet Adm San Antonio, San Antonio, TX USA
[4] Vet Adm Albuquerque, Albuquerque, NM USA
[5] Univ Utah, Salt Lake City, UT USA
[6] Northwestern Univ, Chicago, IL 60611 USA
[7] Univ Texas, Hlth Sci Ctr, San Antonio, TX USA
[8] Univ New Mexico, Albuquerque, NM 87131 USA
[9] Armed Forces Inst Pathol, Bethesda, MD USA
[10] Yale Univ, New Haven, CT USA
关键词
D O I
10.1016/j.jacc.2005.07.071
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We undertook the review of all available cases of hypersensitivity, reactions after placement of a drug-eluting stent (DES) and classified potential causes. BACKGROUND Six months after the approval of the first DES, the Food and Drug Administration (FDA) reported 50 hypersensitivity reactions after stent placement but later concluded these were due to concomitantly, prescribed medications such as clopidogrel. Nevertheless, the FDA continued to receive reports of hypersensitivity. METHODS Reports available from April 2003 through December 2004 for hypersensitivity-like reactions associated with the sirolimus-eluting stent (CYPHER, Cordis Corp., Miami Lakes, Florida) and paclitaxel-eluting stent (TAXUS, Boston Scientific Corp., Natick, Massachusetts) were reviewed. Sources of reports included the FDA's adverse-device-event database, the published literature, and investigators from the Research on Adverse Drug/Device events And Reports (RADAR) project. Causality, was assessed using standardized World Health Organization criteria. RESULTS Of 5,783 reports identified for the DES in the FDA database, 262 unique events included hypersensitivity symptoms. Of these reports, 2 were certainly, and 39 unlikely caused by, clopidogrel and 1 was certainly, 9 probably, and 13 unlikely caused by the DES. From an sources, we identified 17 distinct cases that were probably or certainly, caused by, the stent, of which 9 had symptoms that lasted longer than four weeks. Four autopsies confirmed intrastent eosinophilic inflammation, thrombosis, and lack of intimal healing. CONCLUSIONS The FDA reports and autopsy findings suggest that DES may be a cause of systemic and intrastent hypersensitivity reactions that, in some cases, have been associated with late thrombosis and death.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 19 条
  • [1] [Anonymous], 2004, MOSB DRUG CONS
  • [2] A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
    Babapulle, MN
    Joseph, L
    Bélisle, P
    Brophy, JM
    Eisenberg, MJ
    [J]. LANCET, 2004, 364 (9434) : 583 - 591
  • [3] The Rresearch on Adverse Drug Events and Reports (RADAR) project
    Bennett, CL
    Nebeker, JR
    Lyons, EA
    Samore, MH
    Feldman, MD
    McKoy, JM
    Carson, KR
    Belknap, SM
    Trifilio, SM
    Schumock, GT
    Yarnold, PR
    Davidson, CJ
    Evens, AM
    Kuzel, TM
    Parada, JP
    Cournoyer, D
    West, DP
    Sartor, O
    Tallman, MS
    Raisch, DW
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17): : 2131 - 2140
  • [4] *BOST SCI CORP, 2005, BOST SCI ANN IMPL MI
  • [5] *FDA PUBL HLTH WEB, 2003, INF PHYS SUB THROMB, P2
  • [6] *FOOD DRUG ADM, 2003, UPD INF PHYS SUB THR, P2
  • [7] *FOOD DRUG ADM, 2004, MAN US FAC DEV EXP D
  • [8] Evaluation of metal allergies in patients with coronary stents
    Hillen, U
    Haude, M
    Erbel, R
    Goos, M
    [J]. CONTACT DERMATITIS, 2002, 47 (06) : 353 - 356
  • [9] Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
    Iakovou, I
    Schmidt, T
    Bonizzoni, E
    Ge, L
    Sangiorgi, GM
    Stankovic, G
    Airoldi, F
    Chieffo, A
    Montorfano, M
    Carlino, M
    Michev, I
    Corvaja, N
    Briguori, C
    Gerckens, U
    Grube, E
    Colombo, A
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17): : 2126 - 2130
  • [10] Coronary uptake of gallium-67 citrate after implantation of sirolimus-eluting stent
    Kritharides, L
    Yiannikas, J
    Brieger, D
    Allman, K
    [J]. CIRCULATION, 2004, 109 (17) : 2156 - 2156