Use of nickel implanted boron-doped diamond thin film electrode coupled to HPLC system for the determination of tetracyclines

被引:32
作者
Treetepvijit, S
Preechaworapun, A
Praphairaksit, N
Chuanuwatanakul, U
Einaga, Y
Chailapakul, O [1 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, Mat Chem & Catalysis Res Unit, Bangkok 10330, Thailand
[2] Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
关键词
tetracyclines; nickel-implanted boron-doped diamond; cyclic voltarnmetry; flow injection system; HPLC; amperometric detection;
D O I
10.1016/j.talanta.2005.07.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical analysis of tetracyclines was investigated using nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) by cyclic voltammetry and high performance liquid chromatographic with amperometry. Cyclic voltammetry was used to study the electrochemical oxidation of tetracyclines. Comparison experiments were carried out utilizing as-deposited BDD and glassy carbon electrodes. Ni-DIA electrode provided well-resolved oxidative irreversible cyclic voltammograms and the highest current signals among the electrode studied. High performance liquid chromatography (HPLC) with amperometric detection was also studied. The chromatography was performed using a commercially available Inertsil C18 column, with the mobile phase being: 80% phosphate buffer (pH 2.5)-20% acetonitrile and detected at 1.55 V. The methods were validated over the concentration range 0.05-100 ppm with the overall average recoveries from 83.3 to 102.5% and R.S.D. of less than 10%. The proposed method was further applied to analyse shrimp samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1329 / 1335
页数:7
相关论文
共 35 条
[21]   Platinum particles deposited on synthetic boron-doped diamond surfaces.: Application to methanol oxidation [J].
Montilla, F ;
Morallón, E ;
Duo, I ;
Comninellis, C ;
Vázquez, JL .
ELECTROCHIMICA ACTA, 2003, 48 (25-26) :3891-3897
[22]   Electrochemical fluorination of 1,4-difluorobenzene using boron-doped diamond thin-film electrodes [J].
Okino, F ;
Shibata, H ;
Kawasaki, S ;
Touhara, H ;
Momota, K ;
Nishitani-Gamo, M ;
Sakaguchi, I ;
Ando, T .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (08) :382-384
[23]   Flow injection analysis of tetracycline in pharmaceutical formulation with pulsed amperometric detection [J].
Palaharn, S ;
Charoenraks, T ;
Wangfuengkanagul, N ;
Grudpan, K ;
Chailapakul, O .
ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) :191-197
[24]   CONSTANT POTENTIAL AMPEROMETRIC DETECTION OF CARBOHYDRATES AT A COPPER-BASED CHEMICALLY MODIFIED ELECTRODE [J].
PRABHU, SV ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1989, 61 (08) :852-856
[25]   ELECTROCATALYSIS AND DETECTION OF AMINO-SUGARS, ALDITOLS, AND ACIDIC SUGARS AT A COPPER-CONTAINING CHEMICALLY MODIFIED ELECTRODE [J].
PRABHU, SV ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2258-2263
[26]   Chromatographic methods of analysis of antibiotics in milk [J].
Schenck, FJ ;
Callery, PS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :99-109
[27]   DETERMINATION OF TETRACYCLINE ANTIBIOTICS IN ANIMAL-TISSUES OF FOOD-PRODUCING ANIMALS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION [J].
SOKOL, J ;
MATISOVA, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :75-80
[28]   Rotating ring-disk electrode studies of the oxidation of p-methoxyphenol and hydroquinone at boron-doped diamond electrodes [J].
Sopchak, D ;
Miller, B ;
Avyigal, Y ;
Kalish, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 538 :39-45
[29]   Use of metal complexation in non-aqueous capillary electrophoresis systems for the separation and improved detection of tetracyclines [J].
Tjornelund, J ;
Hansen, SH .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :235-243
[30]   Development and validation of a sensitive method for tetracycline in gingival crevicular fluid by HPLC using fluorescence detection [J].
Vienneau, DS ;
Kindberg, CG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (01) :111-117