Ultrasound contrast agent in intravascular echography: An in vitro study

被引:25
作者
Cachard, C
Finet, G
Bouakaz, A
Tabib, A
Francon, D
Gimenez, G
机构
[1] HOSPICES CIVILS LYON, PATHOL LAB, LYON, FRANCE
[2] HOSPICES CIVILS LYON, DEPT HEMODYNAM & RADIOL, LYON, FRANCE
[3] UNIV LYON 1, F-69365 LYON, FRANCE
[4] CNRS 1216, CREATIS, RES UNIT, LYON, FRANCE
[5] INSERM, CREATIS, RES UNIT, F-69008 LYON, FRANCE
关键词
acoustics; ultrasound contrast agent; intravascular ultrasound; digital image processing;
D O I
10.1016/S0301-5629(97)00010-0
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The intravascular ultrasound image of the intraluminal contour depends on the difference between acoustic impedances of the media which create the endoluminal interface, There are several limitations to the visualization and detection of this interface, These limitations are due to artifacts encountered during image formation and to anatomical complexity, The purpose of this study is to obtain intraluminal contour enhancement using ultrasound contrast agent (UCA), Therefore, our objective was to address the feasibility of this technique by documenting the following: (i) the acoustic properties of UCA at 30 MHz; (ii) in vitro experimentation with tube or postnecrotic artery; and (iii) suitable digital processing, The images obtained with UCA (enhanced image quality) and subtracted from those without UCA provided, after simple digital processing, accurate visualization of the arterial lumen, The image obtained exhibits an even, high-contrast intraluminal edge, Such characteristics facilitate contour extraction by the automated contour detection procedures, (C) 1997 World Federation for Ultrasound in Medicine and Biology.
引用
收藏
页码:705 / 717
页数:13
相关论文
共 31 条
[1]  
BOMMER WJ, 1979, CIRCULATION, V60, P17
[2]   BACKGROUND SUBTRACTION FROM TIME-INTENSITY CURVES IN VIDEODENSITOMETRY - A PITFALL IN FLOW ASSESSMENT USING CONTRAST ECHOCARDIOGRAPHY [J].
BOS, LJ ;
PIEK, JJ ;
SPAAN, JAE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) :1211-1218
[3]   In vitro evaluation of acoustic properties of ultrasound contrast agents: Experimental set-up and signal processing [J].
Cachard, C ;
Bouakkaz, A ;
Gimenez, G .
ULTRASONICS, 1996, 34 (2-5) :595-598
[5]  
CORDAY E, 1984, J AM COLL CARDIOL, V3, P1
[6]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[7]   THE ANGLE OF INCIDENCE OF THE ULTRASONIC BEAM - A CRITICAL FACTOR FOR THE IMAGE QUALITY IN INTRAVASCULAR ULTRASONOGRAPHY [J].
DIMARIO, C ;
MADRETSMA, S ;
LINKER, D ;
THE, SHK ;
BOM, N ;
SERRUYS, PW ;
GUSSENHOVEN, EJ ;
ROELANDT, JRTC .
AMERICAN HEART JOURNAL, 1993, 125 (02) :442-448
[8]   CONTRAST ECHOCARDIOGRAPHY DURING CORONARY ARTERIOGRAPHY IN HUMANS - PERFUSION AND ANATOMIC STUDIES [J].
FEINSTEIN, SB ;
LANG, RM ;
DICK, C ;
NEUMANN, A ;
ALSADIR, J ;
CHUA, KG ;
CARROLL, J ;
FELDMAN, T ;
BOROW, KM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (01) :59-65
[9]   TWO-DIMENSIONAL CONTRAST ECHOCARDIOGRAPHY .1. INVITRO DEVELOPMENT AND QUANTITATIVE-ANALYSIS OF ECHO CONTRAST AGENTS [J].
FEINSTEIN, SB ;
TENCATE, FJ ;
ZWEHL, W ;
ONG, K ;
MAURER, G ;
TEI, C ;
SHAH, PM ;
MEERBAUM, S ;
CORDAY, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :14-20
[10]   ARTIFACTS IN INTRAVASCULAR ULTRASOUND IMAGING - ANALYSES AND IMPLICATIONS [J].
FINET, G ;
MAURINCOMME, E ;
TABIB, A ;
CROWLEY, RJ ;
MAGNIN, I ;
RORIZ, R ;
BEAUNE, J ;
AMIEL, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (07) :533-547