Supercritical fluid chromatography coupled to electrospray mass spectrometry: a powerful tool for the analysis of chiral mixtures

被引:45
作者
Garzotti, M [1 ]
Hamdan, M [1 ]
机构
[1] GlaxoSmithKline SpA, Med Res Ctr, I-37135 Verona, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 770卷 / 1-2期
关键词
chiral stationary phases; SFC; enantiomer separation;
D O I
10.1016/S1570-0232(01)00582-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Supercritical fluid chromatography coupled to a hybrid mass spectrometer (Q-Tof2) equipped with electrospray ion source has been used to separate and characterise a wide range of pharmaceutical racemates. We have chosen diverse molecular structures to demonstrate the potential of such experimental arrangement for high throughput analyses. The use of three different chiral stationary phases and different pressure/temperature working conditions provided clear indications on how such a high throughput method can be developed. The use of mass spectrometry was found to be essential for an unambiguous assignment of the eluting components particularly in the case of complex mixtures. The direct coupling of both systems without the need for a special interface resulted in similar peak shapes and peak widths in the UV and total ion current (TIC) chromatograms. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 13 条
[1]   A COMPARISON OF LC AND SFC FOR CELLULOSE-DERIVED AND AMYLOSE-DERIVED CHIRAL STATIONARY PHASES [J].
BARGMANNLEYDER, N ;
TAMBUTE, A ;
CAUDE, M .
CHIRALITY, 1995, 7 (05) :311-325
[2]   PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY USING A THERMOSPRAY SOURCE IN THE FILAMENT-ON MODE [J].
BERRY, AJ ;
GAMES, DE ;
MYLCHREEST, IC ;
PERKINS, JR ;
PLEASANCE, S .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (02) :105-109
[3]   Importance of stereospecific bioanalytical monitoring in drug development [J].
Caldwell, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :3-13
[4]  
Chilmonczyk Z, 1999, CHIRALITY, V11, P790, DOI 10.1002/(SICI)1520-636X(1999)11:10<790::AID-CHIR9>3.0.CO
[5]  
2-1
[6]   PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY/MASS SPECTROMETRY VIA A 2-STAGE MOMENTUM SEPARATOR [J].
EDLUND, PO ;
HENION, JD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (06) :274-282
[7]   Coupling of a supercritical fluid chromatography system to a hybrid (Q-TOF 2) mass spectrometer: on-line accurate mass measurements [J].
Garzotti, M ;
Rovatti, L ;
Hamdan, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1187-1190
[8]   ONLINE COMBINATION OF SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
MATSUURA, K ;
TAKEUCHI, M ;
NOJIMA, K ;
KOBAYASHI, T ;
SAITO, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) :381-383
[9]   SFC of drug enantiomers [J].
Phinney, KW .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :204A-211A
[10]   Capillary column supercritical fluid chromatography-atmospheric pressure ionisation mass spectrometry -: Interface performance of atmospheric pressure chemical ionisation and electrospray ionisation [J].
Sjöberg, PJR ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :317-327