Coronary stent deployment without predilation in acute myocardial infarction: A feasible, safe, and effective technique

被引:12
作者
Herz, I
Assali, A
Solodky, A
Shor, N
Ben-Gal, T
Adler, Y
Birnbaum, Y
机构
[1] Rabin Med Ctr, Dept Cardiol, IL-49100 Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
关键词
D O I
10.1177/000331979905001104
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Direct percutaneous transcatheter revascularization (PTCR) is becoming an acceptable therapy for acute myocardial infarction (AMI). Stenting in the setting of AMI, once considered contraindicated, is emerging as a suitable option in this situation. Coronary stenting without predilation (SWOP) may potentially shorten the procedure and radiation time, reduce costs, and decrease procedural complications such as coronary dissection and distal embolization. It is expected to cause less vascular injury, with a reduction in the rate of in-stent restenosis. In this preliminary study the authors evaluated the feasibility of the SWOP procedure in 22 selected patients with AMI. Indications for catheter-based myocardial reperfusion were the following: extensive anterior wall MI (68%), inferior wall and right ventricular MI (23%), and inferior wall MI with contraindication for thrombolytic therapy (9%). Patients with cardiogenic shock or with contraindications for aspirin or ticlopidine were excluded. SWOP was successful in 21 attempts (95%), and final procedural success was achieved in all. Proximal or distal dissections were seen in three cases and were treated by additional three stents. Thrombolysis in myocardial infarction (TIMI) flow 3 was restored in all patients. There were no distal embolizations, side branch occlusions, coronary perforations, procedure-related emergency bypass operations, or deaths. It is concluded that in selected patients with AMI, coronary artery stenting without predilation is feasible and safe and does not introduce additional risk to the patients.
引用
收藏
页码:901 / 908
页数:8
相关论文
共 19 条
[1]  
BAIM DS, 1996, CARDIAC CATHETERIZAT, P537
[2]   CORONARY RESTENOSIS - EVALUATION OF A RESTENOSIS INJURY INDEX IN A SWINE MODEL [J].
BONAN, R ;
PAIEMENT, P ;
SCORTICHINI, D ;
CLOUTIER, MJ ;
LEUNG, TK .
AMERICAN HEART JOURNAL, 1993, 126 (06) :1334-1340
[3]  
CARROZZA JP, 1996, CARDIAC CATHETERIZAT, P617
[4]  
DAVIES MJ, 1985, BRIT HEART J, V53, P363
[5]  
EEKHOUT E, 1996, J AM COLL CARDIOL, V27, P757
[6]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[7]   How big are coronary atherosclerotic plaques that rupture? [J].
Fishbein, MC ;
Siegel, RJ .
CIRCULATION, 1996, 94 (10) :2662-2666
[8]   Coronary stent deployment without predilation: Prevention of complications of venous graft angioplasty [J].
Herz, I ;
Assali, A ;
Adler, Y ;
Solodky, A ;
Shor, N ;
Ben-Gal, T ;
Sclarovsky, S ;
Pardes, A .
ANGIOLOGY, 1998, 49 (08) :613-617
[9]  
HERZ I, 1997, AM J CARDIOL, V80, pS31
[10]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254