Detection of biogenic CO production above vascular cell cultures using a near-room-temperature QC-DFB laser

被引:23
作者
Kosterev, AA [1 ]
Tittel, FK
Durante, W
Allen, M
Köhler, R
Gmachl, C
Capasso, F
Sivco, DL
Cho, AY
机构
[1] Rice Univ, Rice Quantum Inst, Houston, TX 77251 USA
[2] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Pharmacol, Houston, TX 77030 USA
[4] Phys Sci Inc, Andover, MA 01810 USA
[5] Bell Labs, Lucent Technol, Murray Hill, NJ 07974 USA
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2002年 / 74卷 / 01期
关键词
D O I
10.1007/s003400100766
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the first application of pulsed, near-room-temperature quantum cascade laser technology to the continuous detection of biogenic CO production rates above viable cultures of vascular smooth muscle cells. A computer-controlled sequence of measurements over a 9-h period was obtained, resulting in a minimum detectable CO production of 20 ppb in a 1-m optical path above a standard cell-culture flask. Data-processing procedures for real-time monitoring of both biogenic and ambient atmospheric CO concentrations are described.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 9 条
[1]   VASCULAR SMOOTH-MUSCLE CELL HEME OXYGENASES GENERATE GUANYLYL CYCLASE STIMULATORY CARBON-MONOXIDE [J].
CHRISTODOULIDES, N ;
DURANTE, W ;
KROLL, MH ;
SCHAFER, AI .
CIRCULATION, 1995, 91 (09) :2306-2309
[2]   HEME OXYGENASE ACTIVITY IN THE ADULT-RAT AORTA AND LIVER AS MEASURED BY CARBON-MONOXIDE FORMATION [J].
COOK, MN ;
NAKATSU, K ;
MARKS, GS ;
MCLAUGHLIN, BE ;
VREMAN, HJ ;
STEVENSON, DK ;
BRIEN, JF .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1995, 73 (04) :515-518
[3]   HEME OXYGENASE ACTIVITY IN BLOOD-VESSEL HOMOGENATES AS MEASURED BY CARBON-MONOXIDE PRODUCTION [J].
GRUNDEMAR, L ;
JOHANSSON, MB ;
EKELUND, M ;
HOGESTATT, ED .
ACTA PHYSIOLOGICA SCANDINAVICA, 1995, 153 (02) :203-204
[4]   Carbon monoxide: An endogenous modulator of the nitric oxide-cyclic GMP signaling system [J].
Ingi, T ;
Cheng, J ;
Ronnett, GV .
NEURON, 1996, 16 (04) :835-842
[5]   Single-mode tunable, pulsed, and continuous wave quantum-cascade distributed feedback lasers at λ congruent 4.6-4.7 μm [J].
Kohler, Rudeger ;
Gmachl, Claire ;
Tredicucci, Alessandro ;
Capasso, Federico ;
Sivco, Deborah L. ;
Chu, S.N. George ;
Cho, Alfred Y. .
Applied Physics Letters, 2000, 76 (09)
[6]   Trace-gas detection in ambient air with a thermoelectrically cooled, pulsed quantum-cascade distributed feedback laser [J].
Kosterev, AA ;
Tittel, FK ;
Gmachl, C ;
Capasso, F ;
Sivco, DL ;
Baillargeon, JN ;
Hutchinson, AL ;
Cho, AY .
APPLIED OPTICS, 2000, 39 (36) :6866-6872
[7]  
KOSTEREV AA, 2002, IN PRESS APPL OPT
[8]   Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor [J].
Morimoto, Y ;
Durante, W ;
Lancaster, DG ;
Klattenhoff, J ;
Tittel, FK .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (01) :H483-H488
[9]  
SUNDERMAN FW, 1982, CLIN CHEM, V28, P2026