On the Overestimation of Early Wall Thickening at the Carotid Bulb by Black Blood MRI, With Implications for Coronary and Vulnerable Plaque Imaging

被引:99
作者
Antiga, L. [2 ]
Wasserman, B. A. [3 ]
Steinman, D. A. [1 ]
机构
[1] Univ Toronto, Toronto, ON M5S 3G8, Canada
[2] Mario Negri Inst Pharmacol Res, Ranica, BG, Italy
[3] Johns Hopkins Univ, Baltimore, MD USA
关键词
black blood MRI; wall thickness; simulation; obliqueness; carotid artery; atherosclerosis;
D O I
10.1002/mrm.21758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Black blood MRI is an attractive tool for monitoring normal and pathological wall thickening; however, limited spatial resolutions can conspire with complex vascular geometries to distort the appearance of the wall in ways hitherto unclear. To elucidate this, a thin-walled cylinder model was developed to predict the composite effects of obliqueness, in-plane resolution and voxel anisotropy on the accuracy of MRI-derived wall thickness measurements. These predictions were validated by means of imaging of a thin-walled carotid bifurcation phantom. Typical thick-slice axial acquisitions were found to result in artifactual wall thickening at the carotid bulb, owing to its obliqueness to the nominal imaging plane. Obliqueness was less problematic for near-isotropic resolutions; however, the obligatory reduction of in-plane resolution served to inflate wall thicknesses uniformly by up to 50%. Moreover, the nonlinear relationship between wall thickness and its overestimation served to mask genuine differences in wall thickness, an effect predicted to be worse for thinner coronary artery walls and plaque caps. Therefore, care must be taken when interpreting black blood MRI wall thickness measurements in the presence- or absence-of observed differences within or between individuals. Magn Reson Med 60:1020-1028, 2008. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:1020 / 1028
页数:9
相关论文
共 29 条
[1]
Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI [J].
Boussel, L ;
Herigault, G ;
de la Vega, A ;
Nonent, M ;
Douek, PC ;
Serfaty, JM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) :413-415
[2]
Coronary risk factors and plaque morphology in men with coronary disease who died suddenly [J].
Burke, AP ;
Farb, A ;
Malcom, GT ;
Liang, YH ;
Smialek, J ;
Virmani, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (18) :1276-1282
[3]
Geodesic active contours [J].
Caselles, V ;
Kimmel, R ;
Sapiro, G .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (01) :61-79
[4]
Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction [J].
Crowe, LA ;
Varghese, A ;
Mohiaddin, RH ;
Yang, GZ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) :416-421
[5]
3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing [J].
Crowe, LA ;
Keegan, J ;
Gatehouse, PD ;
Mohiaddin, RH ;
Varghese, A ;
Symmonds, K ;
Cannell, TM ;
Yang, GZ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (04) :583-588
[6]
DEBAKEY ME, 1985, ANN SURG, V201, P115
[7]
Visualization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging [J].
Hatsukami, TS ;
Ross, R ;
Polissar, NL ;
Yuan, C .
CIRCULATION, 2000, 102 (09) :959-964
[8]
Reproducibility of black-blood coronary vessel wall MR imaging [J].
Hazirolan, T ;
Gupta, SN ;
Mohamed, MA ;
Bluemke, DA .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) :409-413
[9]
Coronary artery wall imaging: Initial experience at 3 Tesla [J].
Koktzoglou, I ;
Simonetti, O ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :128-132
[10]
Submillimeter isotropic resolution carotid wall MRI with swallowing compensation: Imaging results and semiautomated wall morphometry [J].
Koktzoglou, Ioannis ;
Li, Debiao .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :815-823