Computational neural networks for the evaluation of biosensor FIA measurements

被引:29
作者
Hitzmann, B
Ritzka, A
Ulber, R
Scheper, T
Schugerl, K
机构
关键词
biosensors; EnFET; evaluation method; flow injection analysis; neural networks; sample matrix; pH independent;
D O I
10.1016/S0003-2670(97)00153-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A computational neural network based evaluation method is presented, which enables a reliable quantification of enzyme field effect transistor (EnFET) flow injection analysis (FIA) signals from samples with changing pH values. Two FIA systems, one for glucose and the other for urea determination, are employed to test the evaluation method. Measurement signals were obtained from samples with different glucose concentrations (3, 4, 5, 6 and 7 g/l) and urea concentrations (1, 1.25, 1.5, 1.75 and 2.0 g/l) at various pH values (5.5, 5.75, 6.0, 6.25 and 6.5). These signals cannot be evaluated based on the peak height, width or integral. Using a large set of measuring signals for training the artificial neural network (12 samples, each measured fivefold (=60) signals) the error of analyte prediction from test signals are 3.2% and 2.5% for glucose and urea respectively. With a reduced training set of five measurement signals the error of prediction of the test set increases to 4.5% and 5.5% for glucose and urea respectively. In this investigation it will be demonstrated that computational neural networks are able to evaluate FIA signals, which cannot be evaluated reliably by FIA standard methods.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 10 条
[1]   DATA-PROCESSING BY NEURAL NETWORKS IN QUANTITATIVE CHEMICAL-ANALYSIS [J].
BOS, M ;
BOS, A ;
VANDERLINDEN, WE .
ANALYST, 1993, 118 (04) :323-328
[2]   BIO-FIELD-EFFECT TRANSISTORS AS DETECTORS IN FLOW-INJECTION ANALYSIS [J].
BRAND, U ;
REINHARDT, B ;
RUTHER, F ;
SCHEPER, T ;
SCHUGERL, K .
ANALYTICA CHIMICA ACTA, 1990, 238 (01) :201-210
[3]  
CAMPMAJO C, 1992, ANALUSIS, V20, P127
[4]   NEURAL NETWORK BASED RECOGNITION OF FLOW-INJECTION PATTERNS [J].
HARTNETT, M ;
DIAMOND, D ;
BARKER, PG .
ANALYST, 1993, 118 (04) :347-354
[5]   EVALUATION OF PH FIELD-EFFECT TRANSISTOR MEASUREMENT SIGNALS BY NEURAL NETWORKS [J].
HITZMANN, B ;
KULLICK, T .
ANALYTICA CHIMICA ACTA, 1994, 294 (03) :243-249
[6]  
KRUSE H, 1991, PROGRAMMIERUNG NEURO
[7]   WHICH REQUIREMENTS DO FLOW-INJECTION ANALYZER/BIOSENSOR SYSTEMS HAVE TO MEET FOR CONTROLLING THE BIOPROCESS [J].
SCHUGERL, K .
JOURNAL OF BIOTECHNOLOGY, 1993, 31 (03) :241-256
[8]   GLUCOSE-SENSITIVE ENZYME FIELD-EFFECT TRANSISTOR USING POTASSIUM FERRICYANIDE AS AN OXIDIZING SUBSTRATE [J].
SHULGA, AA ;
KOUDELKAHEP, M ;
DEROOIJ, NF ;
NETCHIPOROUK, LI .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :205-210
[9]   GLUCOSE-SENSITIVE FIELD-EFFECT TRANSISTOR WITH ADDITIONAL NAFION MEMBRANE - REDUCTION OF INFLUENCE OF BUFFER CAPACITY ON THE SENSOR RESPONSE AND EXTENSION OF ITS DYNAMIC-RANGE [J].
SOLDATKIN, AP ;
ELSKAYA, AV ;
SHULGA, AA ;
NETCHIPOROUK, LI ;
HENDJI, AMN ;
JAFFREZICRENAULT, N ;
MARTELET, C .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :695-701
[10]   NEURONAL NETWORKS FOR EVALUATION OF MEASURING SIGNALS FROM FLOW-INJECTION ANALYSIS [J].
WASSMANN, A ;
HITZMANN, B .
CHEMIE INGENIEUR TECHNIK, 1993, 65 (08) :947-949