Thick-film graphite electrodes in stripping voltammetry

被引:33
作者
Brainin, K
Henze, G [1 ]
Stozhko, N
Malakhova, N
Faller, C
机构
[1] Tech Univ Clausthal, Inst Inorgan & Analyt Chem, D-38670 Clausthal Zellerfeld, Germany
[2] Urals State Econ Univ, Ekaterinburg 620219, Russia
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 364卷 / 04期
关键词
D O I
10.1007/s002160051339
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various types of modified thick-film graphite electrodes al-e reviewed. Two modification options are available: either in situ modified or beforehand. Electrodes modified in situ by various organic compounds were used for the determination of W, Mo, Cr; Ni and Mn by adsorptive stripping voltammetry. Insoluble inorganic salts, insoluble organic complexes or soluble compounds protected with Nafion were used for modification of the electrode surface beforehand. These pre-conditioned electrodes permit quantification of Pb, Cd, Cu, Zn, Sn, As and HE ions. The detection limits of these elements were in the sub-mu g/L. range. The relative standard deviation did not exceed 10-15%. Measurements were made without deaeration of test solutions and normally without destroying small organic matter found in surface waters. A number of characteristics, such as the formation of well-shaped peaks and stable increments of peaks after standard additions, as well as elimination of the mechanical surface regeneration stage and metallic mercury or its soluble salts from the analytical procedure and a long shelf-life of the electrodes make them promising for electroanalysis and for application in portable field instruments.
引用
收藏
页码:285 / 295
页数:11
相关论文
共 23 条
  • [1] [Anonymous], 1994, ANAL ELECTROCHEMISTR
  • [2] The determination of copper at thin film electrodes by constant current stripping potentiometry
    Bradshaw, MP
    Scollary, GR
    [J]. ELECTROANALYSIS, 1997, 9 (04) : 320 - 324
  • [3] Determination of copper, lead and cadmium in whole blood by stripping voltammetry with the use of graphite electrodes
    Brainina, K
    Schafer, H
    Ivanova, A
    Khanina, R
    [J]. ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 175 - 181
  • [4] BRAININA K, 1993, ELECTROANALYTICAL ST
  • [5] Disposable thick film modified graphite electrodes for stripping voltammetry
    Brainina, KZ
    Ivanova, AV
    Malakhova, NA
    [J]. ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) : 85 - 91
  • [6] CHARACTERIZATION OF THICK-LAYER GRAPHITE DISPOSABLE VOLTAMMETRIC ELECTRODES
    BRAININA, KZ
    BOND, AM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2586 - 2591
  • [7] BRAININA KZ, 1989, 3 BEIJ C EXH INSTR A, pF111
  • [8] BRAININA KZ, 1992, FRESEN J ANAL CHEM, V312, P428
  • [9] BRAININA KZ, 1998, BIOSENSORS DIRECT MO
  • [10] Modified solid electrodes for stripping voltammetric determination of tin
    Faller C.
    Henze G.
    Stojko N.
    Saraeva S.
    Brainina Kh.
    [J]. Fresenius' Journal of Analytical Chemistry, 1997, 358 (6): : 670 - 676