The stenting coronary arteries in non-stress/benestent disease (SCANDSTENT) trial

被引:87
作者
Kelbæk, H
Thuesen, L
Helqvist, S
Klovgaard, L
Jorgensen, E
Aljabbari, S
Saunamäki, K
Krusell, LR
Jensen, GVH
Botker, HE
Lassen, JF
Andersen, HR
Thayssen, P
Galloe, A
van Weert, A
机构
[1] Rigshosp, Cardiac Catheterizat Lab 2013, DK-2100 Copenhagen, Denmark
[2] Skejby Sygehus, Skejby, Denmark
[3] Roskilde Amtssygehus, Roskilde, Denmark
[4] Odense Univ Hosp, DK-5000 Odense, Denmark
[5] Gentofte Amtssygehus, Gentofte, Denmark
[6] Heart Core, Leiden, Netherlands
关键词
D O I
10.1016/j.jacc.2005.10.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of the SCANDSTENT study was to evaluate the use of sirolimus-eluting stents (SES) in complex coronary lesions. BACKGROUND The use of SES improves angiographic and clinical outcomes compared with bare-metal stents (BMS) in simple coronary artery lesions, but there is limited evidence of their safety and efficacy when implanted in complex lesions. METHODS We randomly assigned 322 patients with symptomatic complex coronary artery disease to receive either SES or BMS. The lesions were occluded (36%), bifurcational (34%), ostial (22%), or angulated (8%) in morphology. The primary end point was the difference in minimal lumen diameter six months after stent implantation. RESULTS The patients were well matched in terms of demographic and angiographic baseline characteristics; 18% had diabetes. The reference vessel diameter was 2.86 mm in mean, and the lesion length 18.0 mm. At follow-up, patients who received SES had a minimal lumen diameter of 2.48 mm compared with 1.65 mm in those who received BMS (p < 0.001), a diameter stenosis of 19.3% versus 43.8% (p < 0.001), and 2.0% versus 31.9% developed restenosis (p < 0.001). The rate of major adverse cardiac events was 4.3% with SES versus 29.3% with BMS (p < 0.001), and stent thrombosis was observed in 0.6% in the SES group versus 3.1% in the BMS group (p = 0.15). CONCLUSIONS The use of SES markedly reduced restenosis and the occurrence of major adverse cardiac events in patients with complex coronary artery lesions without increasing the risk of stent thrombosis.
引用
收藏
页码:449 / 455
页数:7
相关论文
共 31 条
[1]   What is the risk of stent thrombosis associated with the use of paclitaxel-eluting stents for percutaneous coronary intervention? A meta-analysis [J].
Bavry, AA ;
Kumbhani, DJ ;
Helton, TJ ;
Bhatt, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (06) :941-946
[2]   Primary stenting versus balloon angioplasty in occluded coronary arteries - The total occlusion study of Canada (TOSCA) [J].
Buller, CE ;
Dzavik, V ;
Carere, RG ;
Mancini, GBJ ;
Barbeau, G ;
Lazzam, C ;
Anderson, TJ ;
Knudtson, ML ;
Marquis, JF ;
Suzuki, T ;
Cohen, EA ;
Fox, RS ;
Teo, KK .
CIRCULATION, 1999, 100 (03) :236-242
[3]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[4]   Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions [J].
Colombo, A ;
Moses, JW ;
Morice, MC ;
Ludwig, J ;
Holmes, DR ;
Spanos, V ;
Louvard, Y ;
Desmedt, B ;
Di Mario, C ;
Leon, MB .
CIRCULATION, 2004, 109 (10) :1244-1249
[5]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[6]  
de Feyter PJ, 2000, Curr Interv Cardiol Rep, V2, P326
[7]   Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions - An intravascular ultrasound analysis [J].
Degertekin, M ;
Serruys, PW ;
Tanabe, K ;
Lee, CH ;
Sousa, JE ;
Colombo, A ;
Morice, MC ;
Ligthart, JMR ;
de Feyter, PJ .
CIRCULATION, 2003, 108 (22) :2747-2750
[8]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]   Coronary in-stent restenosis - predictors, treatment and prevention [J].
Hoffmann, R ;
Mintz, GS .
EUROPEAN HEART JOURNAL, 2000, 21 (21) :1739-1749
[10]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254