Respiratory motion compensation for 3-D freehand echocardiography

被引:16
作者
Atkinson, D [1 ]
Burcher, M [1 ]
Declerck, J [1 ]
Noble, JA [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Med Vis Lab, Oxford, England
基金
英国医学研究理事会; 英国工程与自然科学研究理事会;
关键词
respiration; 3-D echocardiography; optical tracking; motion compensation;
D O I
10.1016/S0301-5629(01)00483-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Motion of the diaphragm during respiration causes a displacement of the heart relative to the position of a transthoracic ultrasound (US) probe. These respiration-induced shifts of cardiac position can lead to spatial misalignments of data when reconstructed in 3-D. We show how to compensate for this motion using a technique that extends the tracking of the probe to additionally monitor a marker placed on the patient umbilicus. The motion of the umbilicus is calibrated to that of the diaphragm using one additional scan. This calibration is used to correct the 3-D spatial positions of cardiac images acquired from multiple acoustic views. At both systole and diastole, segmentations of the endocardial border visually appear more consistent after our correction than with no correction. Long and short axis segmentations should intersect on the endocardium. After correction, their separation at the closest point is shown to be reduced. (E-mail: David.Atkinson@kcl.ac.uk) (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1615 / 1620
页数:6
相关论文
共 14 条
[1]   Patient motion compensation during transthoracic 3-D echocardiography [J].
Chuang, ML ;
Hibberd, MG ;
Beaudin, RA ;
Mooney, MG ;
Riley, MF ;
Fearnside, JT ;
Douglas, PS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (02) :203-209
[2]   ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN [J].
DAVIES, SC ;
HILL, AL ;
HOLMES, RB ;
HALLIWELL, M ;
JACKSON, PC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1096-1102
[3]   Measurement of thoracoabdominal asynchrony: importance of sensor sensitivity to cross section deformations [J].
De Groote, A ;
Verbandt, Y ;
Paiva, M ;
Mathys, P .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (04) :1295-1302
[4]   Chest wall motion during tidal breathing [J].
DeGroote, A ;
Wantier, M ;
Cheron, G ;
Estenne, M ;
Paiva, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1531-1537
[5]   Simultaneous use of two ultrasound scanners for motion-gated three-dimensional fetal echocardiography [J].
Deng, J ;
Ruff, CF ;
Linney, AD ;
Lees, WR ;
Hanson, MA ;
Rodeck, CH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (06) :1021-1032
[6]   MEASUREMENT OF SEPARATE VOLUME CHANGES OF RIB CAGE AND ABDOMEN DURING BREATHING [J].
KONNO, K ;
MEAD, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1967, 22 (03) :407-&
[7]  
NEHRKE K, 2000, P INT SOC MAG RESON, V8, P404
[8]   Rapid calibration for 3-D freehand ultrasound [J].
Prager, RW ;
Rohling, RN ;
Gee, AH ;
Berman, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06) :855-869
[9]  
SCHAFFER RW, 2000, P INT SOC MAGN RESON, V8, P1701
[10]   Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography [J].
Taylor, AM ;
Keegan, J ;
Jhooti, P ;
Firmin, DN ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (02) :131-138