Rapid calibration for 3-D freehand ultrasound

被引:316
作者
Prager, RW
Rohling, RN
Gee, AH
Berman, L
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
[2] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
关键词
3-D freehand imaging; calibration; position sensor;
D O I
10.1016/S0301-5629(98)00044-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
3-D freehand ultrasound is a new imaging technique that is rapidly finding clinical applications, A position-sensing device is attached to a conventional ultrasound probe so that, as B-scans are acquired, they can be labelled with their relative positions and orientations, This allows a 3-D data set to be constructed from the B-scans, A key requirement of all freehand imaging systems is calibration; that is, determining the position and orientation of the B-scan with respect to the position sensor. This is typically a lengthy and tedious process that may need repeating every time a sensor is mounted on a probe. This paper describes a new calibration technique that takes only a few minutes to perform and produces results that compare favourably (in terms of both accuracy and precision) with previously published alternatives. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:855 / 869
页数:15
相关论文
共 25 条
[1]   Three-dimensional freehand ultrasound: Image reconstruction and volume analysis [J].
Barry, CD ;
Allott, CP ;
John, NW ;
Mellor, PM ;
Arundel, PA ;
Thomson, DS ;
Waterton, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1209-1224
[2]  
CARR JC, 1996, THESIS U CANTERBURY
[3]  
CLARKE J, 1996, P 7 BMVC, P415
[4]  
Craig J.J., 1989, INTRO ROBOTICS MECH, DOI 10.7227/IJEEE.41.4.11
[5]   3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION [J].
DETMER, PR ;
BASHEIN, G ;
HODGES, T ;
BEACH, KW ;
FILER, EP ;
BURNS, DH ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :923-936
[6]   3-D ultrasound imaging: A review [J].
Fenster, A ;
Downey, DB .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :41-51
[7]   RANDOM SAMPLE CONSENSUS - A PARADIGM FOR MODEL-FITTING WITH APPLICATIONS TO IMAGE-ANALYSIS AND AUTOMATED CARTOGRAPHY [J].
FISCHLER, MA ;
BOLLES, RC .
COMMUNICATIONS OF THE ACM, 1981, 24 (06) :381-395
[8]   The calibration index and taxonomy for robot kinematic calibration methods [J].
Hollerbach, JM ;
Wampler, CW .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1996, 15 (06) :573-591
[9]   Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor [J].
Hughes, SW ;
DArcy, TJ ;
Maxwell, DJ ;
Chiu, W ;
Milner, A ;
Saunders, JE ;
Sheppard, RJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (05) :561-572
[10]  
KING DL, 1991, J ULTRAS MED, V10, P77