A portable evanescent-wave fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded 10- and 25-g ground beef samples. The biosensor works by launching light from a 635-nm laser diode into specially designed optical fiber probes, generating an evanescent field that extends approximately 1,000 run from the fiber surface. Fluorescent molecules within the evanescent field are excited, and a portion of their emission recouples into the fiber probe. The return path emission is transported by an optical fiber to a photodiode within the biosensor that detects and quantifies the fluorescent signal. A sandwich immunoassay was performed on the fiber probes with cyanine 5 dye-labeled polyclonal anti-E, coli O157:117 antibodies for generation of the specific fluorescent signal. Biotin-streptavidin interactions were used to attach polyclonal anti-E. coli O157:117 antibodies to the surface of the fiber probe. A centrifugation method was developed to obtain samples suitable for biosensor analysis from 10- and 25-g ground beef samples. The assay was shown to be sensitive and repeatable. One hundred percent correct identification of positive samples was demonstrated at 9.0 X 10(3) CFU/g for 25-g ground beef samples with silica waveguides and at 5.2 X 10(2) CFU/g for 10-g ground beef samples with polystyrene waveguides. The reaction was highly specific. No false positives were observed for 10-g ground beef samples not spiked with the pathogen, In addition, when samples were spiked with high concentrations of a variety of non-E. coli O157:117 organisms, no false positives were observed. The method was rapid, with results being obtained within 25 min of sample processing.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 29 条
  • [1] A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION
    ANDERSON, GP
    GOLDEN, JP
    LIGLER, FS
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) : 249 - 256
  • [2] Assay development for a portable fiberoptic biosensor
    Anderson, GP
    Breslin, KA
    Ligler, FS
    [J]. ASAIO JOURNAL, 1996, 42 (06) : 942 - 946
  • [3] A MULTISTATE OUTBREAK OF ESCHERICHIA-COLI-O157-H7 ASSOCIATED BLOODY DIARRHEA AND HEMOLYTIC-UREMIC-SYNDROME FROM HAMBURGERS - THE WASHINGTON EXPERIENCE
    BELL, BP
    GOLDOFT, M
    GRIFFIN, PM
    DAVIS, MA
    GORDON, DC
    TARR, PI
    BARTLESON, CA
    LEWIS, JH
    BARRETT, TJ
    WELLS, JG
    BARON, R
    KOBAYASHI, J
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (17): : 1349 - 1353
  • [4] USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES
    BHATIA, SK
    SHRIVERLAKE, LC
    PRIOR, KJ
    GEORGER, JH
    CALVERT, JM
    BREDEHORST, R
    LIGLER, FS
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) : 408 - 413
  • [5] Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7
    Brewster, JD
    Mazenko, RS
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 211 (1-2) : 1 - 8
  • [6] DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR
    CAO, LK
    ANDERSON, GP
    LIGLER, FS
    EZZELL, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) : 336 - 341
  • [7] Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor
    DeMarco, DR
    Saaski, EW
    McCrae, DA
    Lim, DV
    [J]. JOURNAL OF FOOD PROTECTION, 1999, 62 (07) : 711 - 716
  • [8] Portable multichannel fiber optic biosensor for field detection
    Golden, JP
    Saaski, EW
    ShriverLake, LC
    Anderson, GP
    Ligler, FS
    [J]. OPTICAL ENGINEERING, 1997, 36 (04) : 1008 - 1013
  • [9] THE EPIDEMIOLOGY OF INFECTIONS CAUSED BY ESCHERICHIA-COLI O157-H7, OTHER ENTEROHEMORRHAGIC ESCHERICHIA-COLI, AND THE ASSOCIATED HEMOLYTIC UREMIC SYNDROME
    GRIFFIN, PM
    TAUXE, RV
    [J]. EPIDEMIOLOGIC REVIEWS, 1991, 13 : 60 - 98
  • [10] Hitchins A. D., 1995, Bacteriological Analytical Manual, BAM-8