Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor

被引:93
作者
DeMarco, DR
Saaski, EW
McCrae, DA
Lim, DV [1 ]
机构
[1] Univ S Florida, Dept Biol, Tampa, FL 33620 USA
[2] Res Int, Woodinville, WA 98072 USA
关键词
D O I
10.4315/0362-028X-62.7.711
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A portable fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded ground beef samples. The principle of the system is a sandwich immunoassay using cyanine 5 dye-labeled polyclonal anti-E. cold O157:H7 antibodies for generation of a specific fluorescent signal. Signal acquisition is effected by launching light from a 635-nm diode laser into a dual tapered 600-mu m silica fiber. Fluorescent molecules within approximately 100 nm of the fiber surface are excited by the evanescent field, and a portion of the emission recouples into the fiber. A photodiode allows for quantitation of the collected emission light at wavelengths of 670 to 710 nm. Biotin-avidin interactions are used to attach polyclonal antibodies specific for E. coli O157:H7 to the final 7.5 cm of the fiber probe. The biosensor was able to detect E. coli O157:H7 to 3 to 30 CFU/ mi in seeded ground beef samples. The reaction was highly specific. Signals with Listeria monocytogenes, Salmonella Typhimurium, or E. coli nonO157:H7 were 2 to 3% of those observed with a similar concentration of E. coli O157:H7. Assays were conducted at or near real-time with results obtained within 20 min of sampling.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 25 条
  • [1] A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION
    ANDERSON, GP
    GOLDEN, JP
    LIGLER, FS
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) : 249 - 256
  • [2] Assay development for a portable fiberoptic biosensor
    Anderson, GP
    Breslin, KA
    Ligler, FS
    [J]. ASAIO JOURNAL, 1996, 42 (06) : 942 - 946
  • [3] A MULTISTATE OUTBREAK OF ESCHERICHIA-COLI-O157-H7 ASSOCIATED BLOODY DIARRHEA AND HEMOLYTIC-UREMIC-SYNDROME FROM HAMBURGERS - THE WASHINGTON EXPERIENCE
    BELL, BP
    GOLDOFT, M
    GRIFFIN, PM
    DAVIS, MA
    GORDON, DC
    TARR, PI
    BARTLESON, CA
    LEWIS, JH
    BARRETT, TJ
    WELLS, JG
    BARON, R
    KOBAYASHI, J
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (17): : 1349 - 1353
  • [4] EVALUATION OF METHODS FOR THE ISOLATION AND DETECTION OF ESCHERICHIA-COLI O157 IN MINCED BEEF
    BENNETT, AR
    MACPHEE, S
    BETTS, RP
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 1995, 20 (06) : 375 - 379
  • [5] USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES
    BHATIA, SK
    SHRIVERLAKE, LC
    PRIOR, KJ
    GEORGER, JH
    CALVERT, JM
    BREDEHORST, R
    LIGLER, FS
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) : 408 - 413
  • [6] DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR
    CAO, LK
    ANDERSON, GP
    LIGLER, FS
    EZZELL, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) : 336 - 341
  • [7] Portable multichannel fiber optic biosensor for field detection
    Golden, JP
    Saaski, EW
    ShriverLake, LC
    Anderson, GP
    Ligler, FS
    [J]. OPTICAL ENGINEERING, 1997, 36 (04) : 1008 - 1013
  • [8] THE EPIDEMIOLOGY OF INFECTIONS CAUSED BY ESCHERICHIA-COLI O157-H7, OTHER ENTEROHEMORRHAGIC ESCHERICHIA-COLI, AND THE ASSOCIATED HEMOLYTIC UREMIC SYNDROME
    GRIFFIN, PM
    TAUXE, RV
    [J]. EPIDEMIOLOGIC REVIEWS, 1991, 13 : 60 - 98
  • [9] Hitchins A. D., 1995, Bacteriological Analytical Manual, BAM-8
  • [10] HNATOWICH DJ, 1987, J NUCL MED, V28, P1294