Design, characterization and in vivo performance of synthetic 2 mm-diameter vessel grafts made of PVA-gelatin blends

被引:32
作者
Atlan, M. [1 ,2 ]
Simon-Yarza, T. [1 ]
Ino, J. M. [1 ]
Hunsinger, V. [1 ,2 ]
Corte, L. [3 ,4 ]
Ou, P. [1 ]
Aid-Launais, R. [1 ,5 ]
Chaouat, M. [1 ,6 ]
Letourneur, D. [1 ]
机构
[1] Paris 13 Univ, Paris Diderot Univ, X Bichat Hosp, Lab Vasc Translat Sci,INSERM U1148, F-75018 Paris, France
[2] Univ Paris 06, Hop Tenon, Fac Med, Plast Surg Dept, Paris, France
[3] PSL Res Univ, MINES ParisTech, MAT Ctr Mat, CNRS UMR 7633, BP 87, F-91003 Evry, France
[4] PSL Res Univ, ESPCI Paris, Matiere Molle & Chim, CNRS UMR 7167, F-75005 Paris, France
[5] Paris Diderot Univ, X Bichat Hosp, INSERM UMS 034, FRIM, F-75018 Paris, France
[6] Paris Diderot Univ, Hop St Louis, Burn Unit, Plast Surg Dept, Paris, France
关键词
POLYVINYL-ALCOHOL HYDROGEL; ENGINEERED VASCULAR GRAFT; MECHANICAL-PROPERTIES; SAPHENOUS-VEIN; BLOOD-VESSELS; HEMOCOMPATIBILITY; COMPOSITE; ACCESS; BYPASS; VITRO;
D O I
10.1038/s41598-018-25703-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Since the development of the first vascular grafts, fabrication of vessel replacements with diameters smaller than 6 mm remains a challenge. The present work aimed to develop PVA (poly (vinyl alcohol))-gelatin hybrids as tubes suitable for replacement of very small vessels and to evaluate their performance using a rat abdominal aorta interposition model. PVA-gelatin hybrid tubes with internal and external diameters of 1.4 mm and 1.8 mm, respectively, composed of 4 different gelatin ratios were prepared using a one-step strategy with both chemical and physical crosslinking. By 3D Time of Flight MRI, Doppler-Ultrasound, Computed Tomography angiography and histology, we demonstrated good patency rates with the 1% gelatin composition until the end of the study at 3 months (50% compared to 0% of PVA control grafts). A reduction of the patency rate during the time of implantation suggested some loss of properties of the hybrid material in vivo, further confirmed by mechanical evaluation until one year. In particular, stiffening and reduction of compliance of the PVA-gelatin grafts was demonstrated, which might explain the observed long-term changes in patency rate. These encouraging results confirm the potential of PVA-gelatin hybrids as ready-to-use vascular grafts for very small vessel replacement.
引用
收藏
页数:12
相关论文
共 30 条
[1]
Long term performance evaluation of small-diameter vascular grafts based on polyvinyl alcohol hydrogel and dextran and MSCs-based therapies using the ovine pre-clinical animal model [J].
Alexandre, Nuno ;
Amorim, Irina ;
Caseiro, Ana Rita ;
Pereira, Tiago ;
Alvites, Rui ;
Rema, Alexandra ;
Goncalves, Ana ;
Valadares, Guilherme ;
Costa, Elisio ;
Santos-Silva, Alice ;
Rodrigues, Miguel ;
Lopes, Maria Ascensao ;
Almeida, Andre ;
Santos, Jose Domingos ;
Mauricio, Ana Colette ;
Luis, Ana Lucia .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 523 (02) :515-530
[2]
Biocompatibility and hemocompatibility of polyvinyl alcohol hydrogel used for vascular grafting-In vitro and in vivo studies [J].
Alexandre, Nuno ;
Ribeiro, Jorge ;
Gaertner, Andrea ;
Pereira, Tiago ;
Amorim, Irina ;
Fragoso, Joao ;
Lopes, Ascensao ;
Fernandes, Joao ;
Costa, Elisio ;
Santos-Silva, Alice ;
Rodrigues, Miguel ;
Santos, Jose Domingos ;
Mauricio, Ana Colette ;
Luis, Ana Lucia .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (12) :4262-4275
[3]
Hydrogel fibers for ACL prosthesis: Design and mechanical evaluation of PVA and PVA/UHMWPE fiber constructs [J].
Bach, Jason S. ;
Detrez, Fabrice ;
Cherkaoui, Mohammed ;
Cantournet, Sabine ;
Ku, David N. ;
Corte, Laurent .
JOURNAL OF BIOMECHANICS, 2013, 46 (08) :1463-1470
[4]
Bourke SL, 2003, AAPS PHARMSCI, V5
[5]
The evaluation of a small-diameter polysaccharide-based arterial graft in rats [J].
Chaouat, Marc ;
Le Visage, Catherine ;
Autissier, Aude ;
Chaubet, Frederic ;
Letourneur, Didier .
BIOMATERIALS, 2006, 27 (32) :5546-5553
[6]
In vitro and ex vivo hemocompatibility of off-the-shelf modified poly(vinyl alcohol) vascular grafts [J].
Cutiongco, Marie F. A. ;
Anderson, Deirdre E. J. ;
Hinds, Monica T. ;
Yim, Evelyn K. F. .
ACTA BIOMATERIALIA, 2015, 25 :97-108
[7]
Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings [J].
Fromageau, Jeremie ;
Gennisson, Jean-Luc ;
Schmitt, Cedric ;
Maurice, Roch L. ;
Mongrain, Rosaire ;
Cloutier, Guy .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (03) :498-509
[8]
Saphenous Vein Graft Failure After Coronary Artery Bypass Surgery Pathophysiology, Management, and Future Directions [J].
Harskamp, Ralf E. ;
Lopes, Renato D. ;
Baisden, Clinton E. ;
de Winter, Robbert J. ;
Alexander, John H. .
ANNALS OF SURGERY, 2013, 257 (05) :824-833
[9]
Evaluation of hemocompatibility and endothelialization of hybrid poly(vinyl alcohol) (PVA)/gelatin polymer films [J].
Ino, Julia M. ;
Sju, Ervi ;
Ollivier, Veronique ;
Yim, Evelyn K. F. ;
Letourneur, Didier ;
Le Visage, Catherine .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101 (08) :1549-1559
[10]
Property-based design: optimization and characterization of polyvinyl alcohol (PVA) hydrogel and PVA-matrix composite for artificial cornea [J].
Jiang, Hong ;
Zuo, Yi ;
Zhang, Li ;
Li, Jidong ;
Zhang, Aiming ;
Li, Yubao ;
Yang, Xiaochao .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (03) :941-952