Multiplex Microfluidic Paper-based Immunoassay for the Diagnosis of Hepatitis C Virus Infection

被引:96
作者
Mu, Xuan [1 ]
Zhang, Lin [2 ,3 ]
Chang, Shaoying [1 ]
Cui, Wei [2 ,3 ]
Zheng, Zhi [1 ]
机构
[1] Chinese Acad Med Sci, Sch Basic Med, Peking Union Med Coll, Inst Basic Med Sci, Beijing 100005, Peoples R China
[2] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Lab Med, Beijing 100730, Peoples R China
[3] Peking Union Med Coll, Beijing 100730, Peoples R China
基金
中国国家自然科学基金;
关键词
TO-CUTOFF RATIOS; MULTISTEP ASSAYS; DEVICES; BLOOD; FABRICATION; TIME;
D O I
10.1021/ac500247f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hepatitis C virus (HCV) infection is a serious and rising global healthcare problem. One critical challenge to tackle this disease is the lack of adequate diagnosis. Here, we develop a multiplex microfluidic paper-based immunoassay, as a novel diagnostic approach, to detect human IgG antibody against HCV (anti-HCV). The paper substrate, highly flammable nitrocellulose (NC), is patterned under ambient temperature by craft punch patterning (CPP) to generate multiple test zones. On the basis of superior merits of patterned paper, this new diagnostic approach demonstrates the key novelty to unprecedentedly combine segmented diagnostic assays into a single multiplex test. The generated diagnostic results are not only informative but can be rapidly and cost-effectively delivered. It would significantly transform the clinical pathway for unwitting individuals with HCV infection. This work highlights the promising role of microfluidic paper-based immunoassays in tackling the diagnostic challenge for the HCV pandemic as well as other diseases.
引用
收藏
页码:5338 / 5344
页数:7
相关论文
共 58 条
[1]  
[Anonymous], 2013, LANCET, V381, P178, DOI 10.1016/S0140-6736(13)60070-7
[2]  
[Anonymous], 2013, MMWR-MORBID MORTAL W, V62, P362
[3]  
[Anonymous], 2008, MILL HC FILT DEV RW0
[4]  
[Anonymous], 2012, SIL PAND TACKL HEP C
[5]  
[Anonymous], 2003, U.S. Patent, Patent No. [US 2003/0213838 A1, 20030213838]
[6]   Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing [J].
Apilux, Amara ;
Ukita, Yoshiaki ;
Chikae, Miyuki ;
Chailapakul, Orawon ;
Takamura, Yuzuru .
LAB ON A CHIP, 2013, 13 (01) :126-135
[7]   Study on Enzyme Linked Immunosorbent Assay Using Paper-based Micro-zone Plates [J].
Bai Peng ;
Luo Yan ;
Li Ying ;
Yu Xiao-Dong ;
Chen Hong-Yuan .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (01) :20-24
[8]   Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper [J].
Bruzewicz, Derek A. ;
Reches, Meital ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3387-3392
[9]   Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics [J].
Carrilho, Emanuel ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7091-7095
[10]   Millimeter-scale contact printing of aqueous solutions using a stamp made out of paper and tape [J].
Cheng, Chao-Min ;
Mazzeo, Aaron D. ;
Gong, Jinlong ;
Martinez, Andres W. ;
Phillips, Scott T. ;
Jain, Nina ;
Whitesides, George M. .
LAB ON A CHIP, 2010, 10 (23) :3201-3205