PARAFAC and PARAFAC2 calibration models for antihypertensor Nifedipine quantification

被引:11
作者
Leitao, JMM
da Silva, JCGE
机构
[1] Univ Porto, Dept Chem, Fac Ciencias, P-4169007 Oporto, Portugal
[2] Fac Farm Coimbra, Ctr Estudos Farmaceut, Lab Metodos Instrumentais Anal, P-3000432 Coimbra, Portugal
关键词
antihypertensor Nifedipine; PARAFAC; PARAFAC2; calibration models; alkaline hydrolysis; UV-vis spectroscopy;
D O I
10.1016/j.aca.2005.11.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-way data structures were obtained by acquiring UV-vis spectra as function of the time of the alkaline hydrolysis reaction of the antihypertensor Nifedipine in dimethylsulfoxide (DMSO). Sets of three-way data structures were obtained from the analysis of solutions with different concentrations of Nifedipine generated by standard additions to DMSO, Nifedipine standard and a pharmaceutical formulation. PARAFAC and PARAFAC2 methods were used in the analysis of these multi-way data structures and calibration models were developed for Nifedipine quantification in pharmaceutical formulations. For all the three-way data structures a better model fit was found with the PARAFAC2 suggesting that the experimental data sets have deviations from trilinearity. The best concentrations estimations were found with the PARAFAC2 model in the analysis of a [concentration x time (s) x wavelength (nm)] three-way data structure which allows the quantification of Nifedipine in pharmaceutical formulations. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 30 条
[1]  
Ali S.L., 1989, ANAL PROFILES DRUG S, P221
[2]   The N-way Toolbox for MATLAB [J].
Andersson, CA ;
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 52 (01) :1-4
[3]  
[Anonymous], 1998, Multi-way Analysis in the Food Industry: Models, Algorithms and Applications
[4]   A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[5]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[6]   Exploratory study of sugar production using fluorescence spectroscopy and multi-way analysis [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :133-147
[7]  
Bro R, 1999, J CHEMOMETR, V13, P295, DOI 10.1002/(SICI)1099-128X(199905/08)13:3/4<295::AID-CEM547>3.0.CO
[8]  
2-Y
[9]   Quantification from highly drifted and overlapped chromatographic peaks using second-order calibration methods [J].
Comas, E ;
Gimeno, RA ;
Ferré, J ;
Marcé, RM ;
Borrull, F ;
Rius, FX .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (02) :195-202
[10]  
Cueva JMD, 2001, CHEMOMETR INTELL LAB, V55, P125