Assessment of the mechanical properties of the musculoskeletal system using 2-D and 3-D very high frame rate ultrasound

被引:79
作者
Deffieux, Thomas [1 ]
Gennisson, Jean-Luc [1 ]
Tanter, Mickael [1 ]
Fink, Mathias [1 ]
机构
[1] Univ Paris 07, Lab Ondes & Acoust, UMR 7587, ESPCI,CNRS,INSERM, F-75231 Paris 05, France
关键词
D O I
10.1109/TUFFC.917
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One of the great challenges for understanding muscular diseases is to assess noninvasively the active and passive mechanical properties of the musculoskeletal system. In this paper we report the use of ultrafast ultrasound imaging to explore with a submillimeter resolution the behavior of the contracting tissues in vivo (biceps brachii). To image the contraction, which is a very brief phenomenon (<100 ms), a recently designed ultrasound scanner prototype able to take up to 6000 frames/s was used. A very high frame rate from 1000 to 2500 frames/s was used to image the cross section plane of the muscle (transverse to fibers) enabling us to catch in real time the muscle contraction during a transient electrostimulation. Tissue velocities were obtained from radio frequency-based speckle tracking techniques and their profiles are discussed with respect to electrostimulation intensities and pulse repetition frequencies for different volunteers. Three-dimensional (3-D) very high frame rate movies were also acquired by repeating the experiment for different acquisition planes while triggering the imaging system with the electrostimulation device. The reconstructed 3-D velocity field allows the full localization of the contracting fibers bundle. This ultrasound technique, referred to as echo mechanomyography, offers new perspectives for in vivo and in situ noninvasive muscle diagnosis of an active contractile tissue.
引用
收藏
页码:2177 / 2190
页数:14
相关论文
共 31 条
[11]  
Forrester BJ., 2004, J APPL RES, V4, P346
[12]  
Fung Y. C., 2013, BIOMECHANICS MECH PR
[13]   Human muscle hardness assessment during incremental isometric contraction using transient elastography [J].
Gennisson, JL ;
Cornu, C ;
Catheline, S ;
Fink, M ;
Portero, P .
JOURNAL OF BIOMECHANICS, 2005, 38 (07) :1543-1550
[14]   SKELETAL-MUSCLE CONTRACTION IN HEALTHY-VOLUNTEERS - ASSESSMENT WITH DOPPLER TISSUE IMAGING [J].
GRUBB, NR ;
FLEMING, A ;
SUTHERLAND, GR ;
FOX, KAA .
RADIOLOGY, 1995, 194 (03) :837-842
[15]   Stretch-activated ion channels in the heart [J].
Hu, H ;
Sachs, F .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1997, 29 (06) :1511-1523
[16]   Stretch-induced activation of Ca2+-activated K+ channels in mouse skeletal muscle fibers [J].
Mallouk, N ;
Allard, B .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 2000, 278 (03) :C473-C479
[17]   ELASTOGRAPHY - A QUANTITATIVE METHOD FOR IMAGING THE ELASTICITY OF BIOLOGICAL TISSUES [J].
OPHIR, J ;
CESPEDES, I ;
PONNEKANTI, H ;
YAZDI, Y ;
LI, X .
ULTRASONIC IMAGING, 1991, 13 (02) :111-134
[18]  
ORIZIO C, 1993, CRIT REV BIOMED ENG, V21, P201
[19]   Nonuniform shortening in the biceps brachii during elbow flexion [J].
Pappas, GP ;
Asakawa, DS ;
Delp, SL ;
Zajac, FE ;
Drace, JE .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (06) :2381-2389
[20]  
Patten Carolynn, 2003, Semin Musculoskelet Radiol, V7, P297