The spectrophotometric determination of hydroperoxide and peroxide in a lipid pharmaceutical product by flow injection analysis

被引:10
作者
Bloomfield, MS [1 ]
机构
[1] Glaxo Wellcome Inc, Pharmaceut Dev Sci, Dartford DA1 5AH, Kent, England
关键词
D O I
10.1039/a906243b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, rapid and automatable flow injection analysis procedure is described for the determination of total hydroperoxides and peroxides in lipid products. All unsaturated lipids are susceptible to degradation by oxidation, and the quantification of these major oxidation products is an essential measure of lipid product stability. In this methodology a lipid emulsion is dispersed and injected into an acidic solution of propan-2-ol, which is then merged with iodide ion in situ in a two-stream manifold. The lipid hydroperoxide oxidises acidified iodide to iodine, which is detected spectrophotometrically at 350 nm. The closed conditions prevent interference from atmospheric oxygen and the short reaction time minimises interference from side reactions. Conditions were optimised, using experimental design, for a lipid product under development at GlaxoWellcome. A two-level half-fractional factorial design was applied to screen for the critical factors, followed by a multi-level central composite design to optimise these variables. The resulting method was fully validated and is linear down to 0.1 nmol ml(-1). This approach should be applicable to other lipid formulations and offers significant advantages in terms of speed, automation and precision compared with existing manual procedures.
引用
收藏
页码:1865 / 1871
页数:7
相关论文
共 29 条
[11]   LIPID OXIDATION - MECHANISMS, PRODUCTS AND BIOLOGICAL SIGNIFICANCE [J].
FRANKEL, EN .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1984, 61 (12) :1908-1917
[12]  
Girotti A W, 1985, J Free Radic Biol Med, V1, P87
[13]  
HALLIWELL B, 1990, METHOD ENZYMOL, V186, P1
[14]  
KLEIN RA, 1970, BIOCHIM BIOPHYS ACTA, V210, P486, DOI 10.1016/0005-2736(70)90231-2
[15]  
Kohn HI, 1944, J PHARMACOL EXP THER, V82, P292
[16]  
Martinez-Calatayud J, 1996, FLOW INJECTION ANAL
[17]   MEASUREMENT OF PLASMA HYDROPEROXIDE CONCENTRATIONS BY THE FERROUS OXIDATION XYLENOL ORANGE ASSAY IN CONJUNCTION WITH TRIPHENYLPHOSPHINE [J].
NOUROOZZADEH, J ;
TAJADDINISARMADI, J ;
WOLFF, SP .
ANALYTICAL BIOCHEMISTRY, 1994, 220 (02) :403-409
[18]  
OHISHI N, 1985, BIOCHEM INT, V10, P205
[19]   FLUOROMETRIC FLOW-INJECTION DETERMINATION OF HYDROPEROXIDES IN FOODSTUFFS [J].
PEREZRUIZ, T ;
MARTINEZLOZANO, C ;
TOMAS, V ;
VAL, O .
FOOD CHEMISTRY, 1993, 46 (03) :301-305
[20]  
PRYOR WA, 1984, METHOD ENZYMOL, V105, P293