Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat

被引:96
作者
Kwakye, Sylvia [1 ]
Goral, Vasily N. [1 ]
Baeumner, Antje J. [1 ]
机构
[1] Cornell Univ, Dept Biol & Environm Engn, Ithaca, NY 14853 USA
基金
美国国家科学基金会;
关键词
electrochemical; potentiostat; microfluidic; biosensor; RNA; liposomes;
D O I
10.1016/j.bios.2005.11.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An electrochemical microfluidic biosensor with an integrated minipotentiostat for the quantification of RNA was developed based on nucleic acid hybridization and liposome signal amplification. Specificity of the biosensor was ensured by short DNA probes that hybridize with the target RNA or DNA sequence. The reporter probe was coupled to liposomes entrapping the electrochemically active redox couple potassium ferri/ferrohexacyanide. The capture probes were coupled to superparamagnetic beads that were isolated on a magnet in the biosensor. Upon capture, the liposomes were lysed to release the electrochemical markers that were detected on an interdigitated ultramicroelectrode array in the biosensor just downstream of the magnet. The current was measured, stored and displayed by miniaturized instrumentation (miniEC). The accuracy of the miniEC was evaluated by comparing its performance to a standard bench-top electrochemical workstation in static and dynamic DC amperometric experiments. In both sets of experiments, the inexpensive miniEC performance was comparable in signal strength to that of the electrochemical workstation. In fact, the miniEC achieved a detection limit of 0.01 mu M combined ferri/ferrohexacyanide concentration which was 10x lower than that of the standard lab-bench system. The response time of the miniEC system was the same for low concentrations taking about 10s to steady state. It was, however, slower at higher concentrations, taking 5s versus only 1s for the bench-top system. Finally, the functionality of the miniEC was successfully demonstrated with the detection of Dengue virus RNA. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2217 / 2223
页数:7
相关论文
共 32 条
[1]   RNA biosensor for the rapid detection of viable Escherichia coli in drinking water [J].
Baeumner, AJ ;
Cohen, RN ;
Miksic, V ;
Min, JH .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :405-413
[2]   Biosensor for Dengue virus detection: Sensitive, rapid, and serotype specific [J].
Baeumner, AJ ;
Schlesinger, NA ;
Slutzki, NS ;
Romano, J ;
Lee, EM ;
Montagna, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1442-1448
[3]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[4]   Detection of viable Cryptosporidium parvum using DNA-modified liposomes in a microfluidic chip [J].
Esch, MB ;
Locascio, LE ;
Tarlov, MJ ;
Durst, RA .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2952-2958
[5]   Detection of Cryptosporidium parvum using oligonucleotide-tagged liposomes in a competitive assay format [J].
Esch, MB ;
Baeumner, AJ ;
Durst, RA .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3162-3167
[6]   Integrated chemical/biochemical sample collection, pre-concentration, and analysis on a digital microfluidic lab-on-a-chip platform [J].
Fair, RB ;
Khlystov, A ;
Srinivasan, V ;
Pamula, VK ;
Weaver, KN .
LAB - ON - A - CHIP: PLATFORMS, DEVICES, AND APPLICATIONS, 2004, 5591 :113-124
[7]  
GORAL VN, 2005, UNPUB LAB ON A CHIP
[8]  
HIROAKI S, 2000, ELECTROANAL, V12, P703
[9]   Nucleic acid approaches for detection and identification of biological warfare and infectious disease agents [J].
Ivnitski, D ;
O'Neil, DJ ;
Gattuso, A ;
Schlicht, R ;
Calidonna, M ;
Fisher, R .
BIOTECHNIQUES, 2003, 35 (04) :862-869
[10]  
Iwasaki Y., 1995, CURRENT SEPARATIONS, V14, P1